2-40
INSTALLATION
ORBAN MODEL
B)
Choose whether you wish to program an event that occurs only once or an
event that follows a daily or weekly schedule.
C)
For events that occur only once:
a)
Use the
Prev
and
Next
buttons to move the cursor over the word “
DAILY:
”
and turn the knob so that is reads “
DATE:
” instead.
b)
Use the
Prev
and
Next
buttons to move the cursor to the day, month, and
year when the automation event will occur. Set the desired values with the
knob.
c)
Use the
Prev
and
Next
buttons to move the cursor set the hour, minute, and
second (in 24-hour format) when the automation event is to occur. Set the
desired values with the knob.
D)
For events that occur on a daily or weekly schedule:
a)
Use the
Prev
and
Next
buttons to move the cursor the each day of the week
in turn, and use the rotary encoder to turn the day on or off.
You can program the event to occur on as many days of the week as you
wish.
b)
Use the
Prev
and
Next
buttons to move the cursor set the hour, minute, and
second (in 24-hour format — e.g., 18:00:00 for 6:00 PM) when the
automation event is to occur. Set the desired values with the knob.
Automation events have a “start” time but no “stop” time. The 8600Si
will indefinitely remain in the state specified by an existing automation
event until its state is changed by another automation event or by an-
other action (such as a user’s interacting with the front panel or PC Re-
mote software).
E)
For all events:
a)
Press the
S
ELECT
E
VENT
button.
b)
Turn the knob to set the desired event. The available events are:
•
Recall factory preset
•
Recall user preset
•
stereo mode
•
mono-from-left-channel (
MONO-L
) mode
•
mono-from right-channel (
MONO-R
) mode
•
mono-from-sum-of-channels (
MONO-SUM
)
•
bypass mode
•
Independently activate and defeat the diversity delay applied to the ana-
log, digital, and composite outputs.
•
exit test (restores the operating preset that was on-air before a test mode
Summary of Contents for OPTIMOD-FM 8600Si
Page 1: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Page 7: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Page 56: ......
Page 255: ...OPTIMOD FM DIGITAL OPERATION 3 89...
Page 272: ......
Page 328: ......
Page 330: ...6 28 TECHNICAL DATA ORBAN MODEL 8600Si CONTROL BOARD PARTS LOCATOR...
Page 354: ...6 52 TECHNICAL DATA ORBAN MODEL 8600Si...