2-34
INSTALLATION
ORBAN MODEL 5518
Administering the 5518 through its Serial Port or
Ethernet
Connecting to the 5518’s Ethernet Port or Serial Port via a Ter-
minal Program on a PC
You can connect a terminal emulation application to the 5518’s Ethernet or Serial
ports via TCP/IP, port 23 (which is the standard Telnet port and the 5518 factory de-
fault). When connected like this, you can:
recall presets (step 1 on page 2-37)
turn the diversity delay on and off for a specified output (step 2 on page 2-38)
trim the diversity delay (step 3 on page 2-38)
Select the analog or digital input as the audio source (step 4 on page 2-39)
Fetch real-time operational status information from the Optimod (step 5 on page
2-39)
Fetch information about the active processing preset (step 6 on page 2-40)
Fetch diagnostic information from the 5518 (step 7 on page 2-40)
This interface can be used to allow custom third-party applications (including auto-
mation systems) to recall presets, view status and set the controls listed above. How-
ever, you cannot restore defaults, set security passcodes and change networking
controls via Ethernet or the serial port. You can set those controls by using 5518 PC
Remote software. (See
Installing 5518 PC Remote Control Software
on page 2-47.)
The serial port connection uses the PPP protocol.
To set a different port number:
A)
From the main menu, navigate to
Setup
>
N
ETWORK
&R
EMOTE
>
N
ETWORK
.
B)
Press the
T
ERMINAL
P
ORT
soft button.
The current setting of the Terminal Port appears.
If the
T
ERMINAL
P
ORT
soft button
is not visible, press the
Next/Prev
but-
tons until it is.
a)
Use the
Next
and
Prev
keys to move the cursor in turn to each digit in the
terminal port number. Use the knob to set the digit to the desired value.
Repeat until you have selected all the numbers in the IP address assigned
by your network administrator
b)
Press the
S
AVE
soft button to confirm your setting.
The IP address for this Ethernet connection is the same as the IP address set in
step (1.B) on page 2-42 and is visible in the
Setup
>
N
ETWORK
&R
EMOTE
>
N
ETWORK
Summary of Contents for OPTIMOD-FM 5518
Page 1: ...Operating Manual OPTIMOD FM 5518 FM Stereo Encoder Version 1 2 Software...
Page 7: ...Operating Manual OPTIMOD FM 5518 FM Stereo Encoder Version 1 2 Software...
Page 20: ......
Page 191: ...5518 FM DIGITAL TECHNICAL DATA 6 25...
Page 192: ......
Page 194: ...6 28 TECHNICAL DATA ORBAN MODEL 5518 CONTROL BOARD PARTS LOCATOR...
Page 214: ...6 48 TECHNICAL DATA ORBAN MODEL 5518 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM...