6-4
TECHNICAL DATA
ORBAN MODEL 5518
Maximum Load Capacitance:
0.047
µ
F (0
source impedance). Maximum cable length of
100 feet/30 meters RG–58A/U.
Filtering:
RFI filtered.
Subcarrier (SCA) Inputs
Configuration:
Two subcarrier inputs sum directly into composite baseband outputs;
COMPx LVL control settings have no effect on the absolute subcarrier levels.
Impedance:
600
SCA Sensitivity:
Variable from <100 mV p-p to >10 V p-p to produce 10% injection assum-
ing 100% modulation = 4 V p-p at the 5518’s composite outputs. Rear-panel accessible
PC-board-mounted trim pots allow user to adjust the sensitivities of the two SCA inputs.
Connectors:
Two BNC, shell connected to chassis ground, EMI suppressed.
19 kHz Pilot Reference:
SCA2 input can be re-jumpered to provide a 19 kHz pilot reference
output.
Remote Computer Interface
Supported Computer and Operating System:
IBM-compatible PC running Microsoft Win-
dows® 2000 (SP3 or higher), XP, Vista, or 7.
Configuration:
TCP/IP protocol via direct cable connect, modem, or Ethernet interface.
Suitable null modem cable for direct connect is supplied. Modem and other external
equipment is not supplied.
Serial Connector:
RS–232 on DB–9 male connector, EMI-suppressed. Uses PPP to pro-
vide for direct or modem connection to the 5518 PC Remote application.
Ethernet Connector:
Female RJ45 connector for 10-100 Mbps networks using CAT5 ca-
bling. Native rate is 100 Mbps. Provides for connection to the 5518 PC Remote applica-
tion through either a network, or, using a crossover Ethernet cable, directly to a com-
puter.
Ethernet Networking Standard:
TCP/IP.
Remote Control (GPI) Interface
Configuration:
Eight (8) inputs, opto-isolated and floating.
Voltage:
6–15V AC or DC, momentary or continuous. +12VDC provided to facilitate use
with contact closure.
Connector:
DB–25 male, EMI-suppressed.
Control:
User-programmable for any eight of user presets, factory presets, bypass, test
tone, stereo or mono modes, analog input, digital input.
Filtering:
RFI filtered.
Tally Outputs
Circuit Configuration:
Two NPN open-collector outputs.
Voltage:
+15 volts maximum. Do not apply negative voltage. When driving a relay or other
inductive load, connect a diode in reverse polarity across the relay coil to protect the
driver transistors from reverse voltage caused by inductive kickback.
Current:
30 mA maximum
Indications:
Tally outputs can be programmed to indicate a number of different operational
and fault conditions, including Input: Analog, Input: Digital, Analog Input Silent, AES In-
put Silent, and AES Input Error.
Summary of Contents for OPTIMOD-FM 5518
Page 1: ...Operating Manual OPTIMOD FM 5518 FM Stereo Encoder Version 1 2 Software...
Page 7: ...Operating Manual OPTIMOD FM 5518 FM Stereo Encoder Version 1 2 Software...
Page 20: ......
Page 191: ...5518 FM DIGITAL TECHNICAL DATA 6 25...
Page 192: ......
Page 194: ...6 28 TECHNICAL DATA ORBAN MODEL 5518 CONTROL BOARD PARTS LOCATOR...
Page 214: ...6 48 TECHNICAL DATA ORBAN MODEL 5518 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM...