OPTIMOD 6300 DIGITAL
INSTALLATION
2-27
MULTIBAND
(stereo enhancement, equalization, AGC, and 2-Band or 5-
Band compression without peak limiting)
MB+LIM
(stereo enhancement, equalization, AGC, 2-Band or 5-Band com-
pression, and look-ahead peak limiting)
See step 10 on page 2-14.
J)
Press
N
EXT
. Then set the
DO1
E
MITS
parameter to
S
TEREO
/D
UAL
or
M
ONO
L
.
S
TEREO
/D
UAL
is the normal setting.
M
ONO
L
is for convenience if you are
using the 6300 to process two independent mono programs and you wish
assign each program to a separate digital output. In this case, both chan-
nels of DO1 emit the mono material processed in the 6300’s left channel
and both channels of DO2 emit the right channel material.
K)
Press
N
EXT
. Then adjust
DO1
100%
set the desired digital output level corre-
sponding to 100% modulation, in units of dB below full-scale.
See the notes in step (9.D) on page 2-25.
L)
Navigate to
S
ETUP
>
IO
C
ALIB
>
D
IGITAL
C
ALIB
>
DO2
C
ALIB
and repeat steps (A)
through (K) for Digital Output 2.
11.
Set the 6300’s response to AES3 status bits.
See step (B) on page 2-19.
12.
Choose whether the 6300 digital output will emit status bits depending
on whether the 6300 is in stereo or dual mono modes.
See step (C) on page 2-19.
13.
Choose whether the 6300’s will pass or block AES3 user bits.
See step 22 on page 2-19.
14.
End Analog and Digital I/O setup.
If you are using a external AGC and you temporarily set the
E
XT
AGC
to
NO
in
step 2 on page 2-21, set the
E
XT
AGC
to
Y
ES
.
15.
Select a processing preset.
See step (18.C) on page 2-17.
16.
Program Silence Sense (optional)
You can program the 6300 to switch automatically from its digital input to its
analog inputs if the
I
NPUT
S
OURCE
is set to
D
IGITAL
and the signal at the digital
input falls silent.
There are two silence detectors, one for the analog input and one for the
digital input. The silence sense parameters apply to both simultaneously.
Both detectors are available to drive the 6300's tally outputs but only the
Summary of Contents for OPTIMOD 6300
Page 1: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Page 7: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Page 22: ......
Page 48: ......
Page 94: ...2 46 INSTALLATION ORBAN MODEL 6300 ...
Page 118: ......
Page 200: ......
Page 214: ......
Page 236: ...6 22 TECHNICAL DATA ORBAN MODEL 6300 CONTROL BOARD PARTS LOCATOR ...
Page 242: ...6 28 TECHNICAL DATA ORBAN MODEL 6300 I O DSP BOARD PARTS LOCATOR ...
Page 252: ...6 38 TECHNICAL DATA ORBAN MODEL 6300 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM ...