2-20
INSTALLATION
ORBAN MODEL 6300
23.
Set the Processing Delay for a given signal path (optional).
[minimum], [30 fps], [29.97 fps], [25 fps], [24 fps], [33-50 ms in 1 ms increments]
You can set the delay through the
AGC+LIMIT
and
MB+LIMIT
signal paths inde-
pendently. This feature is usually used in sound-for-picture applications to add
time delay so that the input/output delay through a given processing path is ex-
actly one frame, using a variety of different standards. The selections are
M
INIMUM
(depends on processing structure in use; typically between 20 and 23
ms), 30 fps, 29.97 fps (NTSC color video), 25 fps (most PAL video), and 24 fps
(film). You can also set the delay in 1 millisecond increments.
Navigate to
S
ETUP
>
I/O
C
ALIB
>
P
ROC
D
ELAY
and set the delay as required using
the
AGC+L
IMIT
and
MB+L
IMIT
buttons.
Note that this control does not affect the delay to a given output if that output
is in
AGC
or
M
ULTIBAND
mode.
24.
Set the main display mode (optional).
You can choose how the main display indicates active operating parameters by
navigating to
S
ETUP
>
S
HOW
D
ATE
. Choose
Y
ES
to make the display toggle auto-
matically once every two seconds, displaying the largest range of information.
Choose
N
O
to make the display static, showing the time, the active preset, the ac-
tive input, and whether the stereo or dual-mono mode is active.
The following material provides detailed instructions on how to set up the 6300. If
QUICK SETUP does not fully address your setup needs or if you wish to customize
your system beyond those provided with QUICK SETUP, then you may need the addi-
tional information in the sections below. However, for most users, this material is
only for reference because QUICK SETUP has enabled them to set up the 6300 cor-
rectly.
Analog and Digital I/O Setup
For the following adjustments, use the appropriately labeled soft button to choose
the parameter to be adjusted. To change a parameter (like an output level), it is
usually necessary to hold down the soft button while turning the knob.
1.
Set the MAX LPF frequency as appropriate to your application.
[10.0 kHz] to [20.0 kHz]; 1 kHz steps
The 6300’s lowpass filter is located before any dynamics processing and
affects all outputs equally. It is a phase-linear FIR filter.
The 6300’s audio bandwidth can be set in three places: (1) in Setup, (2) by
remote control, and (3) in the EQ page of the Modify screen. (The latter
allows the active preset to determine the bandwidth so you can change
the bandwidth by recalling a User Preset.)
Summary of Contents for OPTIMOD 6300
Page 1: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Page 7: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Page 22: ......
Page 48: ......
Page 94: ...2 46 INSTALLATION ORBAN MODEL 6300 ...
Page 118: ......
Page 200: ......
Page 214: ......
Page 236: ...6 22 TECHNICAL DATA ORBAN MODEL 6300 CONTROL BOARD PARTS LOCATOR ...
Page 242: ...6 28 TECHNICAL DATA ORBAN MODEL 6300 I O DSP BOARD PARTS LOCATOR ...
Page 252: ...6 38 TECHNICAL DATA ORBAN MODEL 6300 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM ...