OPTIMOD 6300 DIGITAL
INSTALLATION
2-5
6300 Rear Panel
[Note: The 6300’s front panel is described starting on page 3-1.]
The
Power Cord
is detachable and is terminated in a “U-ground” plug (USA stan-
dard), or CEE7 / 7 plug (Continental Europe), as appropriate to your 6300’s Model
Number.
An
RS-232 (PC Remote) Computer Interface,
labeled
S
ERIAL
P
ORT
, is provided to
connect the 6300 to IBM PC-compatible computers, directly or via modem, for re-
mote control, metering and software downloads.
A
Remote Interface Connector
(GPI connector) allows you to connect the 6300 to
your existing transmitter remote control or other simple contact-closure control de-
vices. The 6300 remote control supports user-programmable selection of up to eight
optically isolated inputs for any one of the following parameters: recalling any fac-
tory- or user presets, selecting tone or bypass modes, selecting stereo or dual-mono
mode, selecting analog, digital, or J.17 input, and clock synchronization. (See
Remote Control Interface Programming
on page 2-35.) The 6300 remote control ac-
cepts a DB-25 connector.
The
Ethernet Port
accepts a 10Mb/second or 100Mb/second Ethernet connection
terminated with an RJ45 connector.
Digital AES3 Input
and
AES3 dual Outputs
are provided to support two-channel
AES3-standard digital audio signals through XLR-type connectors.
In dual-mono applications, digital outputs #1 and #2 can be dedicated to
audio channel 1 (left) and channel 2 (right) respectively.
Analog Inputs
and
Outputs
are provided to support left and right audio signals
through XLR-type connectors.
Wordclock / AES11id Sync Input
is provided on a female BNC connector.
The “id” refers to the fact that the connection is unbalanced and is de-
signed to be interfaced with 75
coaxial cable terminated in a male BNC
connector. This input is not internally terminated and requires external
75
termination if it is the last device on the cable.
Input and Output Connections
Cable
We recommend using two-conductor foil-shielded cable (such as Belden 8451 or
equivalent) for the audio input and output connections because signal current flows
through the two conductors only. The shield does not carry signal and is used only
for shielding.
Summary of Contents for OPTIMOD 6300
Page 1: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Page 7: ...Operating Manual OPTIMOD 6300 Digital Multipurpose Audio Processor Version 1 1 Software ...
Page 22: ......
Page 48: ......
Page 94: ...2 46 INSTALLATION ORBAN MODEL 6300 ...
Page 118: ......
Page 200: ......
Page 214: ......
Page 236: ...6 22 TECHNICAL DATA ORBAN MODEL 6300 CONTROL BOARD PARTS LOCATOR ...
Page 242: ...6 28 TECHNICAL DATA ORBAN MODEL 6300 I O DSP BOARD PARTS LOCATOR ...
Page 252: ...6 38 TECHNICAL DATA ORBAN MODEL 6300 FRONT VIEW REAR VIEW FRONT PANEL PARTS LOCATOR DIAGRAM ...