For example, with an STL where 100% modulation = +18dBu, and with a
studio where 0VU = +4dBu:
+18
−
(+4)
−
14 = set gain of the 4000 to 0dB
For facilities using PPM meters, we suggest:
100% peak level (dBu)–PPM reference level (dBu)
−
9db = gain of the 4000
For example, with an STL where 100% modulation = +15dBu, and with a
studio where PPM reference level = +6dBu:
+15
−
(+6)
−
9 = set gain of the 4000 to 0dB
A)
Turn the
IN
(Input) control fully counterclockwise.
B)
Press the
OPERATE
button, then the
TEST
button.
C)
Apply a line-up tone to the 4000 input, at your organization’s standard reference
line-up level.
D)
Calibrate the 4000 for the pre-determined gain or loss.
Measure the output level of the 4000 with an AC level meter. Adjust the
4000’s
IN
control to achieve the desired gain or loss.
E)
Press the
OPERATE
button. Observe the
LIMITING
meter.
If no gain reduction is indicated, the standard line-up level is below thresh-
old.
If gain reduction is indicated, the standard line-up level is above threshold
(less than 7dB below 100% modulation). System calibration will require that
the
TEST
button be pressed, either on the front panel or by remote control,
when system line-up calibration is performed. You may consider calibrating
the 4000 for less than unity gain by reducing the input control setting.
5. Calibrate the 4000’s Input level for normal operation using program
material.
[Skip this step if you wish to calibrate the 4000’s Input level using tone. (Refer
to step 4 on page 2-21.)]
A)
Turn the
IN
(Input) control fully counterclockwise.
B)
Press the
OPERATE
button, then the
TEST
button.
C)
Play program material from your studio at normal levels.
D)
Adjust the
IN
level controls so that the 4000 goes into gain reduction only on the
highest program peaks.
Summary of Contents for OPTIMOD 6200
Page 1: ...Operating Manual OPTIMOD 6200 6200S Digital Audio Processor...
Page 6: ......
Page 7: ...Operating Manual OPTIMOD 6200 6200S Digital Audio Processor...
Page 42: ......
Page 80: ......
Page 142: ...5 8 TROUBLESHOOTING Orban Model 6200 This Page Intentionally Left Blank...
Page 170: ...6 28 TECHNICAL DATA Orban Model 6200...
Page 173: ...OPTIMOD This Page Intentionally Left Blank...
Page 175: ...OPTIMOD TECHNICAL DATA 6 33 PCB ASSEMBLY MAIN 1 98 1 98 1 98 32020 000 03 1 of 1 6200 FC CB CB...
Page 181: ...OPTIMOD TECHNICAL DATA 6 39 SCHEMATIC DSP 2 1 98 1 98 1 98 62020 000 04 6 of 7 6200 FC CB CB...
Page 183: ...OPTIMOD TECHNICAL DATA 6 41 PCA DISPLAY 6200 1 98 1 98 1 98 32016 000 01 1 of 1 6200 FC CB CB...
Page 191: ...OPTIMOD TECHNICAL DATA 6 49...
Page 194: ......
Page 195: ...OPTIMOD DAB TECHNICAL DATA 6 53...