3-28
OPERATION
ORBAN Model 6200
The Multi-Band Structure’s Full Setup Controls
The table shows a summary of the Multi-Band controls:
MULTI-BAND FULL CONTROL
Parameter Labels
Units
Default
Range (CCW to CW)
Step
AGC
---
on
off, on
---
AGC DRIVE
dB (per L/M tables)
−
10 … +25
1
AGC REL
dB/S (per L/M tables)
0.5, 1.0, 1.5, 2 … 20
1
AGC B CPL
% (per L/M tables)
0 … 100
5
BASS CLIP
dB (per L/M tables)
−
6.00 … 0.00
0.25
GATE THR
dB (per L/M tables)
off,
−
44 …
−
15
1
MB DRIVE
dB (per L/M tables)
0 … 25
1
MB REL
--- (per L/M tables)
slow, mslow, mfast, fast
---
B2>B1 CPL
% (per L/M tables)
0 … 100
5
B3>B4 CPL
% (per L/M tables)
0 … 100
5
B4>B5 CPL
% (per L/M tables)
0 … 100
5
B5 THR
dB (per L/M tables)
−
16 … 0
0.3
DWNEXP THR
dB
(per preset)
off,
−
6 … +12
0.5
FINAL LIMT
dB (per L/M tables)
0.00 … 6.00
0.25
LESS-MORE
---
(per preset)
(read-only)
---
PARENT PRESET
---
(per preset)
(read-only)
---
Table 3-5: Multi-Band Controls
These controls are explained in detail below.
Each Multi-Band Factory Preset has a
LESS-MORE
control that adjusts on-air loudness
by altering the amount of processing.
LESS-MORE
simultaneously adjusts all of the
processing controls to optimize the trade-offs between unwanted side effects.
If you wish, you may adjust the
FULL CONTROL
parameters to your own taste. Always
start with
LESS-MORE
to get as close to your desired sound as possible. Then edit the
FULL CONTROL
parameters using the Full Control screen, and save those edits to a User
Preset.
AGC ON/OFF control activates or defeats the slow AGC prior to the multi-band com-
pressor.
AGC DRIVE control adjusts signal level going into the slow AGC, and therefore deter-
mines the amount of gain reduction in the AGC. This also adjusts the “idle gain” — the
amount of gain reduction in the AGC section when the structure is gated. (It gates when-
ever the input level to the structure is below the threshold of gating.)
The total amount of gain reduction in the Multi-Band structure is the sum of the gain
reduction in the AGC and the gain reduction in the multi-band compressor. The total
system gain reduction determines how much the loudness of quiet passages will be in-
creased (and, therefore, how consistent overall loudness will be). It is determined by the
Summary of Contents for OPTIMOD 6200
Page 1: ...Operating Manual OPTIMOD 6200 6200S Digital Audio Processor...
Page 6: ......
Page 7: ...Operating Manual OPTIMOD 6200 6200S Digital Audio Processor...
Page 42: ......
Page 80: ......
Page 142: ...5 8 TROUBLESHOOTING Orban Model 6200 This Page Intentionally Left Blank...
Page 170: ...6 28 TECHNICAL DATA Orban Model 6200...
Page 173: ...OPTIMOD This Page Intentionally Left Blank...
Page 175: ...OPTIMOD TECHNICAL DATA 6 33 PCB ASSEMBLY MAIN 1 98 1 98 1 98 32020 000 03 1 of 1 6200 FC CB CB...
Page 181: ...OPTIMOD TECHNICAL DATA 6 39 SCHEMATIC DSP 2 1 98 1 98 1 98 62020 000 04 6 of 7 6200 FC CB CB...
Page 183: ...OPTIMOD TECHNICAL DATA 6 41 PCA DISPLAY 6200 1 98 1 98 1 98 32016 000 01 1 of 1 6200 FC CB CB...
Page 191: ...OPTIMOD TECHNICAL DATA 6 49...
Page 194: ......
Page 195: ...OPTIMOD DAB TECHNICAL DATA 6 53...