OPTIMOD-FM DIGITAL
INSTALLATION
2-5
This file is also available from the / 8300 / Documentation / Vxxx folder at Orban’s
ftp site, ftp.orban.com.
8300 Rear Panel
The
Ground Lift Switch
can be set to connect the 8300’s circuit ground to its chas-
sis ground (in the
G
ROUND
position). In the
L
IFT
position, it breaks that connection.
(See
Set Ground Lift switch
on page 2-3.)
The
Voltage Select switch
can be set to 115V (for 90-130V operation) or 230V (for
180-260V operation).
Fuse
values can be changed to support 115V or 230V operation. For safety, use ½-A
250V Slow-Blow for 115V, or 250mA-250V for 230V.
The
Power Cord
is detachable and is terminated in a “U-ground” plug (USA stan-
dard), or CEE7 / 7 plug (Continental Europe), as appropriate to your 8300’s Model
Number.
An
RS-232 (PC Remote) Computer Interface,
labeled
S
ERIAL
P
ORT
, is provided to
connect the 8300 to IBM PC-compatible computers, directly or via modem, for re-
mote control, metering and software downloads.
A
Remote Interface Connector
allows you to connect the 8300 to your existing
transmitter remote control or other simple contact-closure control devices. The 8300
remote control supports user-programmable selection of up to eight optically iso-
lated inputs for any one of the following parameters: recalling any factory- or user
presets, tone or bypass modes, selecting stereo encoder modes (stereo, mono-left,
mono-right, mono-sum), selecting analog, digital or J.17 input, overshoot
compensation, SCA modulation compensation, and clock synchronization. (See
Re-
mote Control Interface Programming
on page 2-36.) The 8300 remote control ac-
cepts a DB-25 connector.
The
Ethernet Port
accepts a 10Mb/second or 100Mb/second Ethernet connection
terminated with an RJ45 connector.
Digital AES3 Input
and
Output
are provided to support two-channel AES3-
standard digital audio signals through XLR-type connectors.
Analog Inputs
and
Outputs
are provided to support left and right audio signals
through XLR-type connectors.
Two
Composite Baseband Outputs
are provided, each with independent output
level control. Each output uses a BNC connector.
Two
SCA Inputs
are provided for stations that use additional subcarriers (SCAs).
Each input uses a BNC connector. The second SCA input can be reconfigured via an
internal hardware jumper as a Pilot Reference Output useful for RDS (RBDS) subcar-
rier generators that require an external sync reference.
Summary of Contents for 8300J
Page 1: ...Operating Manual OPTIMOD FM 8300 Digital Audio Processor Version 2 1 Software...
Page 7: ...Operating Manual OPTIMOD FM 8300 Digital Audio Processor Version 2 1 Software...
Page 24: ......
Page 94: ...2 46 INSTALLATION ORBAN MODEL 8300 This page intentionally left blank...
Page 190: ......
Page 204: ......
Page 246: ......
Page 247: ...OPTIMOD FM DIGITAL TECHNICAL DATA 6 29...
Page 254: ...6 36 TECHNICAL DATA ORBAN MODEL 8300 CPU Module...
Page 260: ...6 42 TECHNICAL DATA ORBAN MODEL 8300 8300 RS232 BOARD PARTS LOCATOR...
Page 262: ...6 44 TECHNICAL DATA ORBAN MODEL 8300 8300 POWER SUPPLY PARTS LOCATOR...
Page 264: ...6 46 TECHNICAL DATA ORBAN MODEL 8300 8300 I O BOARD PARTS LOCATOR...
Page 270: ...6 52 TECHNICAL DATA ORBAN MODEL 8300 DSP BOARD PARTS LOCATOR DRAWING 32170 000 14...
Page 278: ...6 60 TECHNICAL DATA ORBAN MODEL 8300 8300 DISPLAY BOARD PARTS LOCATOR...
Page 279: ...OPTIMOD FM DIGITAL TECHNICAL DATA 6 61 DISPLAY BOARD...