3-30
OPERATION
ORBAN MODEL 8300
Although it is located in the Full Modify screen (to make it easy for a preset devel-
oper to switch meter modes), this control is
not
part of the active preset and its set-
ting is not saved in User Presets, unlike the other controls in the Full Modify screens.
The meter mode always reverts to
M
ASTER
when the user leaves Full Modify.
Advanced AGC Controls
The following AGC controls are available only in the 8300 PC Remote software.
AGC Maximum Delta Gain Reduction
determines the maximum gain difference
permitted between the two channels of the AGC. Set it to “0” for perfect stereo
coupling.
This control works the same regardless of whether the AGC operates in left/right or
sum/difference
M
ATRIX
modes, in both cases controlling the maximum gain difference
between the “channels.” Depending on the
M
ATRIX
mode setting, the “channels” will
handle left and right signals or will handle sum and difference signals. When the
AGC operates in sum/difference
M
ATRIX
mode, this control determines the maximum
amount of width change in the stereo soundfield.
AGC Window Size
determines the size of the “target zone” window in the AGC. If
the input level falls within this target zone, the AGC release time is set to the num-
ber specified by the AGC
W
INDOW
R
ELEASE
control. This is usually much slower than
the normal AGC release, and essentially freezes the AGC gain. This prevents the AGC
from building up density in material whose level is already well controlled. If the
level goes outside the window, then the AGC switches to the release rate specified
by
AGC
M
ASTER
R
ELEASE
, so the AGC can still correct large gain variations quickly.
The normal setting for the AGC
W
INDOW
S
IZE
is 3 dB.
AGC Window Release
(see AGC
W
INDOW
S
IZE
above.)
AGC Matrix
allows you to operate the AGC in left/right mode, or in sum/difference
mode. Usually you will operate in left/right mode. However, sum/difference mode
can give a type of stereo enhancement that is different from the enhancement
modes offered in the 8300’s built-in stereo enhancer. This will only work if you allow
the two channels of the AGC to have different gains. To do this, set the
AGC
M
AXIMUM
D
ELTA
G
AIN
R
EDUCTION
control greater than zero.
It is unwise to set this control beyond 3 dB. Multipath distortion could increase be-
cause the amount of L–R energy builds up excessively. We prefer using the 8300’s
stereo enhancer because its built-in gating circuits prevent over-enhancement.
AGC Ratio
determines the compression ratio of the AGC. The compression ratio is
the ratio between the change in input level and the resulting change in output
level, both measured in units of dB.
Previous Orban AGCs had compression ratios very close to
:1, which produces the
most consistent and uniform sound. However, the 8300 compressor can reduce this
Summary of Contents for 8300J
Page 1: ...Operating Manual OPTIMOD FM 8300 Digital Audio Processor Version 2 1 Software...
Page 7: ...Operating Manual OPTIMOD FM 8300 Digital Audio Processor Version 2 1 Software...
Page 24: ......
Page 94: ...2 46 INSTALLATION ORBAN MODEL 8300 This page intentionally left blank...
Page 190: ......
Page 204: ......
Page 246: ......
Page 247: ...OPTIMOD FM DIGITAL TECHNICAL DATA 6 29...
Page 254: ...6 36 TECHNICAL DATA ORBAN MODEL 8300 CPU Module...
Page 260: ...6 42 TECHNICAL DATA ORBAN MODEL 8300 8300 RS232 BOARD PARTS LOCATOR...
Page 262: ...6 44 TECHNICAL DATA ORBAN MODEL 8300 8300 POWER SUPPLY PARTS LOCATOR...
Page 264: ...6 46 TECHNICAL DATA ORBAN MODEL 8300 8300 I O BOARD PARTS LOCATOR...
Page 270: ...6 52 TECHNICAL DATA ORBAN MODEL 8300 DSP BOARD PARTS LOCATOR DRAWING 32170 000 14...
Page 278: ...6 60 TECHNICAL DATA ORBAN MODEL 8300 8300 DISPLAY BOARD PARTS LOCATOR...
Page 279: ...OPTIMOD FM DIGITAL TECHNICAL DATA 6 61 DISPLAY BOARD...