1.
Select the Drive Element Addressing Mode from the list. The options are:
Address All Drive Slots (Recommended)
All drives, including empty drive slots, are assigned a sequential SCSI element
address which is always reported to attached hosts. In this mode, the library does
not need to be restarted for newly installed drives to become usable by attached
hosts, and drive SCSI element addresses never change. Also, empty drive slots
can be assigned to a partition.
You should select this setting if using STA. Otherwise, media validation drives will
not show within STA.
Address Only Installed Drives
Only installed drives are assigned a sequential SCSI element address. Empty
drive slots are not assigned a SCSI element address and are not reported to
attached hosts. In this mode, the library must be restarted before newly installed
drives are usable by attached hosts, and drive SCSI element addresses may
change. Also, only installed drives can be assigned to a partition.
You must select this setting if using ACSLS.
2.
Tap Next.
Configure the Library Step 5 of 6: Configure the Mailslot, Reserved
Slots and Volume Label Format
Configure the mailslot type, number of reserved system slots, and volume label format.
Note:
Code versions before 2.0 will not include an option for mailslot configuration.
1.
Configure the mailslot.
Chapter 2
Configure the Library After Powering-on for the First Time
2-38