How to Replace a ZS3-4 Fan Module
6.
Slide the replacement drive into the slot until it is fully seated.
7.
Close the latch to lock the drive in place.
8.
The Oracle ZFS Storage system software automatically detects and configures
the new drive. The device appears in the BUI Maintenance > Hardware screen
when you view details for the controller or drive shelf.
How to Replace a ZS3-4 Fan Module
Caution -
Operating a controller for an extended period of time with fans removed reduces the
effectiveness of the cooling system. For this reason, the replacement fan should be unpacked in
advance and ready to insert into the controller chassis as soon as the faulted fan is removed.
Fan modules are hot-swappable and can be removed and installed while the storage controller is
running without affecting other hardware capabilities. Use the following procedure to replace a
ZS3-4 fan module.
1.
To locate the chassis you want to service, click the associated locator icon
on the Maintenance > Hardware screen of the BUI or issue the
set /SYS/LOCATE
status=on
command at the service processor (SP) prompt. The locate LED will
flash on the controller chassis.
Servicing the Hardware
93