Testing the Installation
Callout
Description
1
Low profile mounting bracket (standard)
2
Port 1 SAN LED
3
Port 1 LC Connector
4
Port 2 LC Connector
5
Port 2 SAN LED
6
Port 1 LAN LED
7
Port 2 LAN LED
The following table summarizes the LED status conditions.
Green LED (LAN Traffic)
Green LED (SAN Traffic)
Activity
Off
Off
Power off
Slow flashing (unison)
Slow flashing (unison)
Power on (no link)
On
On
Link established; no activity
Flashing
On
Link established; transmit and receive LAN only activity
On
Flashing
Link established; transmit and receive SAN only activity
Flashing
Flashing
Link established; transmit and receive LAN and SAN activity
Off
On or flashing
Fatal error detected on LAN function; SAN functioning
normally
On or flashing
Off
Inconsistent state detected on Fibre Channel firmware state
machine; unable to recover
Off
Off
MPI firmware initialization failed (incorrect checksum, invalid
config image, or EDC PHY firmware load failure), or the MPI
firmware asserts during runtime and hangs permanently
Slow flashing (alternating)
Slow flashing (alternating)
Beaconing
Testing the Installation
This section contains the following topics:
■
“To Verify Proper Installation (Oracle SPARC Systems)” on page 28
■
“To Verify Attached Storage (Oracle SPARC Systems)” on page 30
Chapter 2 • Hardware Installation and Removal
27
Summary of Contents for 7105381
Page 2: ......