Description of the basic operation
OPTIMUM
M A S C H I N E N - G E R M A N Y
15 / 06 / 2011
Page 30
Description of the basic operation Digital position display DPA 2000/ DPA 2000S ; Version 2.1.2
©
201
1
GB
displayed on the corresponding coordinate axis. The axes which do not associate with the
selected coordinate layer will not be displayed.
The indicator light to the left of the
key is illuminated, indicating that the X-axis is the
default axis.
If you want to change the coordinate layer, just press the
key several times, the coordinate plane will change according to the following
sequences:
To change from the XY coordinate layer into the YZ coordinate;
To change from the YZ coordinate layer into the XZ coordinate layer;
After quitting the dividing hole on the circle function, the position display resumes the
standard display.
Entering the position of the center of the circle:
-
Select coordinate axis and the indicator light of this axis is illuminated;
-
Enter a new coordinate value;
-
Press the
key to confirm the value;
-
Repeat the above three steps to finish entering the two coordinates for the center;
-
Press the
key to prepare the entry of the following parameter.
The display screen on the upper right will show
indicating that you may
now enter the diameter value.
The LEDs on the X-axis will display the diameter value of the last input. The last entered value
will be displayed on the LEDs on the Y-axis.
Enter the diameter value of the circle and then press the
key to confirm the value.
The display screen on the upper right will show
indicating that you can
enter the number of holes to be divided now.
The LEDs on the X-axis will display the last entered number of holes divided. The last ente-
red value will be displayed on the LEDs on the Y-axis.
Enter the number of divided holes. Press the
key to confirm the entry.
The display screen on the upper right will show
indicating that you may
now start entering the value of the starting point angle.
The LEDs on the X-axis will display the value of the starting point angle of the last entry. The
last entered value will be displayed on the LEDs on the Y-axis.
Enter the value of the starting point angle and press the
key to confirm the value.
The display screen on the upper right will show
indicating that you may
enter the value of the end point angle.
The LEDs on the X-axis will display the last entered value of the end point angle. The last
entered value will be displayed on the LEDs on the Y-axis.