5.4.3
Cleaning the electrical cabinet
Although the electrical cabinet is con-
structed to shut off external air, foreign parti-
cles such as dust and dirt may enter the
cabinet when the door is open.
Accumulation of foreign particles on the
printed circuit boards or other electronic
components could cause machine malfunc-
tion.
Clean the inside of the electrical cabinet
regularly.
Remove dust
inside electrical cabinet with a vacuum cleaner. Do not use com-
pressed air to clean the electrical cabinet.
Never touch circuit boards or parts around the connector. Also
avoid hitting these parts with the vacuum.
We recommend that the electrical cabinet is cleaned every 1000
operating hours.
The illustrated control cabinet key is included in the accessories.
5.4.4
Refilling the oil in the central lubrication system
The central lubrication system lubricates important functional parts of the milling machine. The
maximum fill amount is 2 litres. If levels drop below the minimum fill amount, an audible alarm is
triggered. The central lubrication system is equipped with an switch. The switch deactivates
central lubrication. Make sure that the central lubrication does not remain permanently swit-
ched off.
Abb.5-2: Central lubrication system
INFORMATION
If the overload fuse of the pump motor trips, the motor switches off for about 5 minutes
to cool down.
Please press the manual button for no longer than 2 minutes to prevent an overload.
Filler hole
Manual trigger, lubrication
interval
Max. fill level
Min. Fill level
Time setting
Summary of Contents for 3346245
Page 1: ...GB Operating Manual Version 1 0 4 Milling machine Item no 3346245 ...
Page 97: ...Version 1 0 4 2020 7 31 97 Originalbetriebsanleitung MZ4S DE EN MZ4S_parts fm ...
Page 98: ...Version 1 0 4 2020 7 31 98 Originalbetriebsanleitung MZ4S DE EN MZ4S_parts fm ...
Page 99: ...Version 1 0 4 2020 7 31 99 Originalbetriebsanleitung MZ4S DE EN MZ4S_parts fm ...
Page 100: ...Version 1 0 4 2020 7 31 100 Originalbetriebsanleitung MZ4S DE EN MZ4S_parts fm ...
Page 101: ...Version 1 0 4 2020 7 31 101 Originalbetriebsanleitung MZ4S DE EN MZ4S_parts fm ...