- 16 -
5. Although the gate has been closed and locked properly, the blades do not move
down.
- The safety switch at the lock needs readjustment.
- The electricity supply is interrupted. Check fuses at power unit.
6. The blades do not close properly although the spade cylinders are fully extended.
-
Guides are worn and must be replaced.
-
Blades are bent and have to be adjusted.
7.
One function (any) does not work.
- The electricity supply is interrupted. Check power circuit.
- The magnet of the respective control valve is defect. Valve must be replaced.
-
The plunger of the control valve is seized, probably due to a dirt particle in the
hydraulic oil. Disassemble valve and clean.
Summary of Contents for 1100
Page 15: ... 13 Illustration 10 Illustration 11 Illustration 12 Illustration 13 ...
Page 19: ... 17 ...
Page 24: ......
Page 30: ......
Page 32: ......
Page 34: ......
Page 37: ......
Page 40: ......
Page 42: ......
Page 47: ......