Chapter-2
Before Using
NLV-5201 User's Manual
23
1st
Installation of the Scanner
2.9
The installation of the scanner is described as below.
・
Mount the scanner using the assigned screw holes on the bottom or side.
・
Do not screw down further than the limitation of its depth.
・
The scanner’s anti-shock reliability is confirmed only in case impulse (acceleration) is applied via the
contact surface. However, the scanner cannot withstand direct shock since it consists of precise
optical elements.
NLV-5201 Installation
Recommend screw type: M3
Recommend torque:
Less than 20 Ncm.
Maximum screw depth:
3.5 mm from the mounting surface of the scanner.
Dimensions: Approx. 41.1 (W) ×33.0 (H) ×24.0 (D)
Weight:
Approx. 30 g (excluding cable)
Cable:
1.5 m
Please contact sales for 3D CAD data.
Mounting Holes
M3 Depth 3.5
41.1
33
10.9
12
24
35.9
15
8
18.8
Mounting Holes
M3 Depth 3.5
11
2.6
X X X X X X
13.11
[Unit: mm]