Chapter-2
Before Using
NLV-5201 User's Manual
17
1st
Control Panel Operation Specifications
2.7.2
Operation specification of the control panel allocated on the side of housing are as follows.
LED Indication Mode Key Trigger Key
Operation
Mode
Operation description
Trigger Key
for reading
Normal
Normal operation status.
Press once
(within 2 sec)
Mode
transition by
pressing once
Test
Used when testing the read rate.
The read rate is displayed on the indicator LED
every 10 times.
Press twice
(within 2 sec)
Mode
transition by
pressing once
Tuning
Tuning automatically perform optimum exposure
setting etc. according to the read code. When the
tuning is successes, the code is limited, and
exposures setting etc. are registered to the current
bank. Also, the reading rate when tuning is
successes is displayed on the LED indicator.
Press 3 times
(within 2 sec)
Mode
transition by
pressing once
Aiming
In the aiming mode, aiming lights and if code can
be read, displays whether the code is close to the
center coordinate of the image sensor to indicator
LED.
Press 4 times
(within 2 sec)
Press
2 seconds
or more
(Press again
to select)
Mode
transition by
pressing once
Bank
selection
By pressing the mode key for more than 2
seconds, the bank currently used will be display on
the LED. Pressing the mode key again, bank
becomes selectable in order, and by pressing the
trigger key, the bank displayed becomes effective.
Press both key at same
time for 5 seconds,
becomes initialization
standby. And initialize by
pressing trigger key again.
Initialize
Pressing mode key and trigger key at same time
for 5 seconds, it enters to the initialization standby.
Initialized by pressing trigger key with that status,
and initialization standby will be cancel by pressing
mode key.