background image

Power (OFF)

2

3

Be sure to use the power supply of 

100 to 240 VAC. 
Otherwise it may cause fire or 
electric shock.

Do not wipe the 

Transmitter with solvent. 
It may cause failure.

To clean the 

Transmitter, first wipe 
away lightly with a clean 
soft cloth damped by 
diluted mild detergent 
solution and then wipe 
off moisture with a dry 
clean soft cloth.

100 to 240 VAC

Organi

c

Solvent

Thinner

etc.

There are high 

voltage parts inside 
the Transmitter. 

 

Failure to observe 
this precaution may 
cause fire or an 
electric shock.

Do not give a strong shock to the 

Transmitter.

Do not press the CLEAN button, while 

the SS Checker (Detector) is in the air. 

Make sure that the Cover is locked 

without fail. Otherwise, protective 
structure may not function adequately.

Keep the Power off during 
installation and wiring operations.

Use Cable Clamps attached to the 

transmitter for wiring. When the piping 
are directly connected with  the 
transmitter, take a corrective action 
such as caulking against intrusion of 
gas because corrosive gas is in danger 
of intruding through the piping, etc. into 
the Transmitter. 

Do not bind the signal output cable with 

the power cable or do not put them in 
the one Cable Clamp.

Install the transmitter 

with attached 
Mounting Bracket.

Install the transmitter at a place 

ventilating well and avoiding direct 
sunlight.

Do not disassemble or modify the 

Transmitter. Disassembly or 
modification may cause fire or an 
electric shock because there are high-
voltage parts inside the Transmitter.

Turn off the Power immediately 

i

n the 

unlikely event that there occur any 
abnormalities such as smoke or 
abnormal noise. Otherwise it may 
cause fire or an electric shock.

Please thoroughly read the "For safe use" before using the SC-T4 
properly.
Because these precautions are related to failure or malfunction, 
observe the precautions for use without fail.

In order to use the SC-T4 properly, 
observe the following precautions.

Precautions which are the cause of failure: 

The SC-T4 is used exclusively to SS Checker (Detector). 
Accordingly, do not connect other equipment.

[Be sure to read this instruction manual in order 
to use the Transmitter SC-T4 properly.]

1

For safe use

"      " denotes "Prohibited action", and "      " denotes "Required action".

Summary of Contents for SS Checker SC-T4

Page 1: ...is instruction manual should be kept for future reference such as maintenance Transmitter Instruction Manual 2007 7 59 1362 1 For more information on OPTEX products contact your dealer or visit our we...

Page 2: ...ture reference such as maintenance Transmitter Instruction Manual 0 1 Table of Contents 1 For safe use 2 External Features 3 Installation Installation Wiring Extension of Detecter Cable 4 Operation Pa...

Page 3: ...ve gas is in danger of intruding through the piping etc into the Transmitter Do not bind the signal output cable with the power cable or do not put them in the one Cable Clamp Install the transmitter...

Page 4: ...t On Transmitter Operation panel Display 2 External Features Cover Cable Clamps Key Hook Lock Lever Power Switch Circuit Breakers Terminal Block Operation Buttons Display Terminal Cover Alarm Level In...

Page 5: ...luding wiring resistance For connection to the Self Checking Relay Output terminal and Alarm Relay Output terminal load resistance should be 240 VAC and 1A Max Although a protective circuit is built i...

Page 6: ...o carry out Fine Adjustment of Signal Output Low Limit 4mA Press the upper and lower arrow buttons simultaneously to carry out Fine Adjustment of Signal Output High Limit 20mA Move the digit to be ent...

Page 7: ...d water or ion exchange water 1 Clean the Detector and the Detector Windows Every time the MODE button is pressed the Display is changed into each setting To change the setting value select the item a...

Page 8: ...s not 1000 use to change the Display into 1000 indication When the display shows 1000 press to terminate the 0 Span Adjustments 8 Press for 2 seconds or more SPAN blinks on the Display Pip Pip Pip 4 A...

Page 9: ...ayed the value is out of the setting range Alarm Timer can be set for 1 to 120 minutes or OFF Setting unit is 1 minute The Alarm Timer is set for OFF as a factory setting Alarm Timer Setting Ex To set...

Page 10: ...d lower arrow buttons button increases a numeric value and button decreases the value While pressing buttons the values displayed are continuously changed To cancel the Signal Output Low Limit Setting...

Page 11: ...Pip Pip Fine Adjustment of Signal Output 6 Fine Adjustment of Lower Limit 4mA and Upper Limit 20mA of Signal Output 4 20mA can be made When both right and left arrow buttons are pressed simultaneously...

Page 12: ...es measured by the official method and the values indicated by SC T4 at a place where the instrument is installed Indicated values Indicated values 1 2 The following calculating formula is used Span s...

Page 13: ...indicated on the Display Err 5 is indicated on the Display The Detector is out of order A Detector Cable is not wired properly The Detector is out of order A Detector Cable is not wired properly The D...

Page 14: ...Power Supply for Sensor 12 VDC Signal Output analog 4 20mA resistance load of 300 or less Self checking Relay Output non voltage C contact capacity 240 VAC 1A resistance load Alarm Relay Output non vo...