8-2
8.1
Torque Signal Measurement Unit
Input Section
Amplifier
Isolated unbalanced DC amplification
Input signal
Phase difference conversion type detector output signal
Input impedance
About 2k
Ω
(with an input signal amplitude of 2Vpp or less)
Input frequency range
200Hz to 50kHz
Input signal amplitude range
0.2Vpp to 15Vpp
Connector
TRC116-23A10-7F (Tajimi Electronics)
Setup Section
Capacity
±
1-9999
Factor
1 to 65535
Unit
mNm, Nm, kNm
Number of teeth of detector
P/R 1 to 9999
Torque zero compensation value
CW/CCW Memorized in memory for each direction.
Response
Time constant setting
16ms/31ms/63ms/125ms/250ms/500ms/1s/2s/4s/8s/16s/32s/64s
OFF is added only when the TS-0321 option is mounted.
Number of display digits
(Po 4 digits (default)) / (Po 5 digits) selectable
Measurement Section
Measurement clock
4.195MHz
Sampling clock
Sampling time for one data 1/256Hz (about 4ms)
Display Section
Number of display digits
(Po 4 digits) / (Po 5 digits) selectable
Unit
mNm/Nm/kNm
Display gate time setting
1s to 10s (shared with the rotating section) or external gate
Accuracy
When combined with the detector (with 1s gate time)
N-0 compensation used:
±
0.2% / full-scale
±
1 count
(4-digits)
N-0 compensation not used:
±
0.5% / full-scale
±
1 count
(4-digits)
Summary of Contents for TS-3200A
Page 1: ...TS 3200A DIGITAL TORQUE METER INSTRUCTION MANUAL ONO SOKKI CO LTD...
Page 21: ...Chapter 2 Before Use 2 1 Name and Function of Each Section 2 2 Detector Connections...
Page 96: ...4 30...
Page 143: ...6 1 Chapter 6 Menus 6 1 MENU Key 6 2 CAL Key 6 3 TRQ ZERO Key...
Page 150: ...6 8...
Page 151: ...7 1 Chapter 7 Troubleshooting...
Page 154: ...7 4...
Page 167: ...8 13 Panel cutout dimensions 4 M5 370 405 100 1 0 50 0 5 4 2 6 34 301 12 8 Specifications...
Page 169: ...8 15 4 2 6 34 301 12 8 Specifications...
Page 170: ...8 16...