1
USER NOTICES
☆
When the unit is operating, the total capacity of the indoor units should be no more than the
capacity of outdoor unit. Otherwise, it can cause the shortage of cooling capacity (heating
capacity) of each indoor unit.
☆
The power supply of the indoor unit must be the unified power supply. The indoor unit cannot
have the individual power switch, and the entire indoor unit can only be controlled by one
main power control. Disconnect the main power of all the indoor units before cleaning.
☆
In order to start the unit successfully, the general power supply switch of the air-conditioning
units should be turned to the “ON” position for 8 hours before running.
☆
After each of indoor units received the stop running signal, the fan motor of the indoor unit
will use the surplus cool or surplus heat of the heat exchanger go on running for 20-70 seconds,
this is the preparation for the next time use and this is the normal phenomenon.
☆
When the selected mode of the indoor unit co nflict with the mode of outdoor unit, after 5
seconds, the wired remote control will display the operation conflict, the indoor unit will stop
running, then to unify the running modes of the indoor unit and outdoor unit, the unit will get
right. There is no conflict in the COOL mode and DRY mode, the FAN mode will not conflict
with any other modes.
☆
The appliance shall not be installed in the laundry
☆
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should
be connected in fixed wiring
☆
Missing information regarding electric supply tole/-10%, +/-1Hz) in documentation
☆
Missing information regarding humidity (30-95%) in documentation