Wired Remote Controller Operation Procedure
5)
Temp. adjusting
(
Fig.17
)
When not setting the time
,
press
and
button
,
can
set the temperature adjustment.
For increasing setting temperature
;
For decreasing setting temperature
。
(
When press this button
,
the temperature will be increased or
decreased in the unit of 1
The temperature setting range is 16
30
at every kind off
modes
6)
Set of running mode
(
Fig.18
)
When pressing MODE button each time
,
the mode will be
changed as following
:
COOL
DRY
FAN
HEAT
At “COOL” mode
,
the COOL display will be light on
,
the
temperature of setting should be lower than the room
temperature. If the setting temperature is higher than the
room sensor
,
the unit will not run at cool mode operation
.
At “DRY” mode
,
the DRY display will be light on. Fan
motor will run at low fan speed in the definite temperature
range. The dehumidifying effect of this mode is better than that
in COOL mode and more energy saving.
At “HEAT” mode
,
the HEAT display will be light on. The
temperature should be set higher than the room temperature
;
If
the setting temperature is lower than the room temperature, the
unit will not run at HEAT mode operation.
At
“
FAN
”
mode
,
the FAN display will light on.
7)
Malfunction display
(
Fig.19
)
When the malfunction happened during the operation, the
environment temperature display area will show the error code.
As shown in Fig.19 it shows the compressor high-pressure
protection.
When the malfunction happened
,
except for the FAN mode is in
operation
,
at the mode of COOL, DRY, HEAT ,the outdoor unit
and fan motor are closedown
,
that will not affect the LCD
display.
ON/OFF
TIMER
FAN
MODE
SLEEP
ON/OFF
TIMER
FAN
MODE
SLEEP
ON/OFF
TIMER
FAN
MODE
SLEEP
Fig.17
Fig.18
Fig.19