![Onicon F-5500 Installation And Operation Manual Download Page 89](http://html.mh-extra.com/html/onicon/f-5500/f-5500_installation-and-operation-manual_1636043089.webp)
F1
F2
F3
F4
"LL"
NOMINAL LENGTH
COMPRESSION FITTING,
3/4" TUBE, 316 SST
RETAINING RING
Ø.75 [19.1]
.73 [18.5]
6.70 [170.2]
FLOW DIRECTION
INDICATOR
2X SET SCREW
4.64 [118.0]
PROBE
PROCESS ADAPTER FITTING
SUPPLIED WITH METER
ELECTRONICS
ENCLOSURE
4.31 [109.5]
6.09 [154.7]
THREADOLET, 1" OUTLET,
CARBON STEEL
6.32 [160.5]
2X 3/4" FNPT
PORTS
BALL VALVE, 1 IN. FEMALE NPT,
FULL PORT, BRONZE
2.60 [66.1]
INSTALL KIT
INSTALL KIT, INSTALLED
AT INSTALLATION
NOTE: PROCESS ADAPTER FITTING &
INSTALL KIT SHOWN ASSEMBLED
PROCESS ADAPTER FITTING
C SENSING AREA
L
Collar
Screwed stop
Cable
HIGH PRESSURE
PROCESS ADAPTER
FITTING
Spacer
STANDARD
PROCESS ADAPTER FITTING
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]
F-5500 Thermal Mass Flow Meter Manual 06/17 - 2030 / 107023
Page 89
Model F-5500
APPENDICES
Insertion with
Process
Adapter
Fitting
Fig. 7.1 Insertion Meter with Process Adapter Fitting Dimensions
Measurements shown in inches (millimeters).
Table 7.1 Insertion Meter with 316 stainless steel
probe
Appendices: Dimensions
Process Adapter Fitting
Dimension “LL”
[inches / millimeters]
15.0" (381 mm)
18.0" (457 mm)