Run-Mode Measurement Process
Individual Data
How to get Individual Data Output
1.
Parallel ‘DO 0 to 31’Signals
Only integer value is output. (Data is rounded to the nearest integer.) Data
is output in 2’ s complement format in 16-bits at a time. When two or more
data are defined, 16-bits values are output sequentially.
When measurement value is “+1234”
2.
Serial Communication via RS-232C/422, USB, Ethernet
It doesn’t needed to send the command from external device (e.g. PC,
PLC). If you set “Data output = ON” (See below description about setting),
Individual data are automatically output after measurement is finished.
3.
To SD-Card
If you set “Data output = ON” (See below description about setting), Indi-
vidual data are automatically output after measurement is finished.
Setting about Individual Data
MENU mode - [System] - [Output] - [Data output]
Setting about Individual Data (Parallel)
DO15 DO14 DO13 DO12 DO11 DO10 DO9 DO8 DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
0
0
0
0
1
1
0
0
0
1
0
0
1
0
0
1
Setup Item
Description
RS-232C/422
Selects ON to output data on the RS-232C/422 interface.
(default value: OFF)
Parallel
Selects ON to output data via the parallel port. (default value: OFF)
SD card
Selects ON to output data to the SD card. (default value: OFF)
USB
Selects ON to output data via the USB port. (default value: OFF)
Ethernet
Selects [ON] to output data on an Ethernet connection.
(default value: OFF)
MENU mode - [System] - [Comm] - [Parallel]
Output Polarity (OR, DO[0:15])
This is same setting as
Individual Judgement.
(See the previous page)
Output cycle
Gate ON delay
Gate ON time
Handshaking
Timeout