13
1-5 Installing the C-mount Cameras
Preparation
is not required and the value “t5.0” shows the case where a 5-mm Extension
Tube is used.
Example
When a 3Z4S-LE ML-5018 CCTV Lens is being used and a detection range of
40 mm is required at the measurement target, a camera distance of 500 mm
and 5-mm Extension Tube are required.
1-5-2
Installing the Camera Mounting Base
The camera mounting base mounted on the bottom of the camera can be
installed on all of the four mounting surfaces. To change the mounting surface,
remove the three mounting screws (M2 x 6) from the camera.
• Tightening torque when fastening the camera mounting base at the
mounting location
M4: 1.2 Nm
1/4”-20 UNC: 2.6 Nm
Extension Tube t_ (mm)
Camera
Lens
Measurement object
Camera distance A (mm)
Detection range L (mm)
Camera Mounting Base
Z01E-EN-01+ZFX+SettingGuide.book Seite 13 Mittwoch, 13. Februar 2008 2:38 14