11
1-4 Installing the Intelligent Cameras
Preparation
1-4-2
Installing the mounting fixture
The mounting fixture can be installed on all of the four mounting surfaces.
1.
Align the two hooks on one side of
the mounting fixture with the two
grooves on the camera body.
2.
Push the other hook down until it
is snapped into place.
Make sure that the mounting fix-
ture is firmly fixed on the camera.
3.
Fasten the mounting fixture at the
mounting location with screws.
Tightening torque
M4: 1.2 Nm
1/4”-20 UNC: 2.6 Nm
Removal procedure
1.
Insert a screwdriver into the gap
(one of the two gaps) between the
mounting fixture and the camera
case, and remove the mounting
fixture.
1-4-3
Adjusting the camera focus
1.
Adjust the distance between the
camera and the measurement tar-
get and fasten the camera.
Refer to the optical chart and set
the camera in a position so that
the area to be checked is within
the detection area (LCD monitor).
“Optical chart” p. 10.
2.
Turn the focus adjustment control
to the left and right to adjust the
focus.
Note
First turn the focus adjustment control slightly to the left and right, to make
sure that the Focus adjustment control is not at the upper or lower limit posi-
tions. Do not exert unnecessary force to turn the control at the upper or lower
limit positions as this might damage the control.
(For ZFX-SC90_/SC150_, the control stops turning at the nearest position. It
turns free at the farthest position.)
Hooks
Grooves on camera
Mounting
fixture
Mounting fixture
Setting distance (L)
Detection range (H)
Focus
adjustment
control
Z01E-EN-01+ZFX+SettingGuide.book Seite 11 Mittwoch, 13. Februar 2008 2:38 14