22
2-4 Position Correction
Main Operation
2-4
Position Correction
This function is used when the position or orientation of measurement target
is no fixed. If you use this function, the amount of the shift from the reference
position iscalculated, and the position of the measurement region is corrected
before measurement is performed.
Important
Use a saved image, when setting the position correction.
If you use an image different from the one that was initially used for position
correction, position correction might not be set correctly. Moreover, set the
measurement items again, if you use a different image.
Recommended procedural
TEACH
process
Image input
TEACH process
of measurement Item
Measuring the
area of grey part
Image input
Position Correction
Measurement
TEACH process
of Position Correction
Inspection
With Position
Correction
“Position Correction” recognizes
the amount of the position shift.
“Position Correction” fixes the
position of measurement region.
Inspect
Image sw
Setup menu
Capture
SD
Region
0.Pattern
Register model
Reference model
Search region
Reference point
TEA
Region
Img Adj
Detail
Limits
Saving the image into SD card
Position correction
Registering the live image
Push [Image SW]. After that
,
the
image which is used for position
correction is switched.
MENU mode - [Setup] - [Register] - [Image 0] - [Register image] - [Live image]
MENU mode - [Setup] - [Register] - [Image 0] - [Save to SD card]
--> In case that you need to adjust the position correction
,
you can use the same
image in SD card.