124

AC  servo systems

General specifications

I/O specifications

Terminal specifications

 Sp

e

e

d/

to

rque 

con

tr

o

l mode

Perform

a

nc

e

Speed control range

1:5000

Speed
variance

Load variance

During 0 to 100% load ±0.01% max. (at rated speed)

Voltage variance

Rated voltage ±10%: 0% (at rated speed)

Temperature variance

25 ±25 °C: ±0.1 % max (at rated speed)

Frequency characteristics

400Hz (at J

L

= J

M

)

Torque control accuracy (reproducibility)

±2%

Soft start time setting

0 to 10s (acceleration, deceleration can each be set.)

Inp

ut

 signal

Speed 
reference 
input

Reference voltage

±6VDC (forward motor rotation if positive reference) at rated speed: Set at delivery
Variable setting range: ±2 to ±10 VDC at rated speed/ max. input voltage: ±12 V

Input empedance

Approx. 14 k

Ω

 

Circuit time constant

-

Torque 
reference
input

Reference voltage

±3 VDC (forward rotation if positive reference) at rated speed: Set at delivery
Variable setting range ±1 to ±10 VDC at rated torque reference

Imput impedance

Approx. 14 K

Ω

Circuit time constant

Approx. 47

 

µs

Contact 
speed 
reference

Rotation direction selection

With P control signal

Speed selection

With forward/reverse current limit signal (speed 1 to 3 selection), servo motor stops or another control method is 
used when both are OFF.

Position

 control

 m

ode

P

e

rf

o

rma

nc

e

Bias Setting

0 to 450 min

-1

  (setting resolution: 1 min

-1

Feed forward compensation

0 to 100 % (setting resolution: 1%)

Position completed width setting

0 to 250 command units (setting resolution: 1 command unit)

Inpu

t signal

Command 
pulse

Input pulse type

Sign + pulse train, 90° phase displacement 2-phase pulse (A-phase+ B-phase) or CCW/CW pulse train

Input pulse form

Line driver (+5 V level) , open collector (+5 V or +12 level)

Input pulse frequency

0 to 500 Kpps (200 Kpps max. at open collector)

Control signal

Clear signal (input pulse is same as reference pulse)

I/

O si

g

n

a

l

Position signal output

A-phase, B.phase, C-phase, (S-phase): line driver output  S-phase is for absolute encoder only.

Sequence input signal

Servo ON, P control (or control mode switching, zero clamp, command pulse inhibit), forward/reverse run
prohibit, alarm reset, forward/ reverse current limit (or internal speed switching)

Sequence output signal

Servo alarm, alarm codes (3-bit output): CN1 output terminal is fixed
It is possible to output three types of signals form among: positioning complete (speed agree), motor rotation, 
servo ready, current limit, speed limit, brake release, warning, NEAR, and zero point pulse signal

 In

te

gr

a

ted  

funct

ions 

Communications Interface

Digital operator (hand- held type), RS-422 port for PCs, etc. (RS-232C ports under some conditions)

1:N communications

N may equal up to 14 when an RS-422A port is used. 
CompoWay/F protocol is supported on firmware version "3.20C" and higher

Axis address setting

Set by user setting

Functions

Status display, user constant setting monitor display, alarm traceback display, JOG run /autotuning  operations, 
and graphing functions for speed/torque command signal, etc

PROFIBUS

(Only models with PROFIBUS) PROFIBUS DP slave, node address 0-125 set by rotary switches, baud rate from 
9.6 kbps to 12 Mbps. LED Indicators: Bus failure and system failure

Auto tuning function

Position speed  loop gain and integral time constant can be automatically set.

Dynamic brake (DB)

Operates during main power OFF, servo alarm, servo OFF or overtravel

Regenerative processing

Regenerative resistor externally mounted (option)

Overtravel (OT) prevention function

DB stop, deceleration stop or coast to stop during P-OT, N-OT operation

Encoder divider function

Optional division possible

Electronic gearing

0,01< A/B<100

Internal speed setting function

3 speeds may be set internally

Protective functions

Overcurrent, overvoltage, insufficient voltage, overload, main circuit sensor error, heatsink overheat, power phase 
loss, overflow, overspeed, encoder error, runaway, CPU error, parameter error, etc.

Analog monitor functions for supervision

Integrates analog monitor connectors for supervision of the speed and torque reference signals, etc.

Display functions

CHARGE, POWER, 7-segments LEDx5 
(Integrated digital operator function, not available in models with PROFIBUS) 

Others

Reverse connection, zero search, automatic motor discrimination function, and DC reactor connection terminal 
for high frequency power suppression function (except: 6 to 15 kW)

Symbol

Name

Function

L1, L2 or
L1, L2, L3

Main circuit AC input terminal

AC power input terminals for the main circuit

U

Servo motor connection terminal

Red

Terminals for outputs to the servo motor.

V

White

W

Blue

L1C, L2C

Control power input terminal

AC power input terminals for the control circuit.

Frame ground

Ground terminal. Ground to a maximum of 100

Ω

. (class 3)

B1, B2 or
B1, B2, B3

Main circuit DC output terminal

5 kW or less: Connect an external regenerative resistor if regenerative energy is high.
5.5 kW: There is no internal regenerative resistor. Be sure to connect an external regenerative resistor unit.

1, 

2

DC reactor connection terminal for sup-
pressing power supply harmonic waves 

Normally, short 

1 and 

2. If a countermeasure against power supply harmonic waves is needed, 

connect a DC reactor between 

1 and 

2.

Main circuit DC output terminal (+)

Normally, not connected.
This terminal exists on the servo drives with a capacity opf 6.0 kW or higher only.

Main circuit DC output terminal (n-)

Normally, not connected.

Y203-EN2-02-Katalog.book  Seite 124  Mittwoch, 24. Mai 2006  2:22 14

Summary of Contents for XTRADRIVE -

Page 1: ...s supported it allows remote access to the drives through the PLC Ratings 230 VAC single phase 30 W to 1 5 kW 4 77 Nm 400 VAC three phase 0 5 kW to 5 0 kW 28 4 Nm System configuration Cables Cables CH...

Page 2: ...N XD 15 TSD0 11 5 N m 1 8 kW XD 20 TN XD 20 TSD0 18 6 N m 2 9 kW XD 30 TN XD 30 TSD0 28 4 N m 4 4 kW XD 50 TN SGMSH 3000 min 1 400 V 3 18 N m 1 0 kW XD 10 TN XD 10 TSD0 4 90 N m 1 5 kW XD 15 TN XD 15...

Page 3: ...1 1 7 3 8 Servo drive type XD 05 T XD 10 T XD 15 T XD 20 T XD 30 T XD 50 T Applicable servo motor SGMAH 03D 07D SGMPH 02D 04D 08D 15D SGMGH 05D 09D 13D 20D 30D 44D SGMSH 10D 15D 20D 30D 40D 50D SGMUH...

Page 4: ...under some conditions 1 N communications N may equal up to 14 when an RS 422A port is used CompoWay F protocol is supported on firmware version 3 20C and higher Axis address setting Set by user settin...

Page 5: ...e stop stops reference pulse input when ON 42 43 P OT N OT Forward run prohibited Reverse run prohibited Overtravel prohibited stops servo motor when movable part travels beyond the allowable range of...

Page 6: ...PCO Phase C signal 48 49 PSO PSO Phase S signal With an absolute encoder Outputs serial data corresponding to the number of revolutions RS 422 or the equivalent 37 38 39 1 ALO1 ALO2 ALO3 Alarm code ou...

Page 7: ...HARGE POWER CN3 CN1 CN2 149 5 0 5 12 75 130 6 160 149 5 5 5 75 5 75 12 63 5 6 10 5 5 160 8 2 5 holes CN10 Ground terminal 2 M4 screws Terminal block 5 2 M4 screw holes Mounting hole diagram Mounting p...

Page 8: ...N1 CN3 CN1 CN2 CN3 6 8 196 CN10 14 pin terminal M4 mounting screw 250 238 5 6 100 110 75 180 4 5 5 5 5 250 238 5 0 5 100 0 5 110 5 5 5 5 6 39 CHARGE POWER Ground terminal 2 M4 screws Name plate Mounti...

Page 9: ...1 11 06 291 11 46 GNYE wires AWG16 355 13 98 35 1 38 118 4 65 18 0 71 1 2 0 05 5 0 20 10 0 39 19 0 75 80 3 15 100 3 94 5 0 0 02 0 245 9 65 0 5 0 0 02 0 5 0 20 10 0 39 M4 4 Units mm in Model R88A FIW40...

Page 10: ...t OFF for an alarm Photocoupler output Max operating voltage 30 VDC Max operating current 50 mA DC Speed coincidence detection ON when speed coincides Alarm code output Max operating voltage 30 VDC Ma...

Page 11: ...eds the settings Servo ready output ON when ready Servo alarm output OFF for an alarm Photocoupler output Max operating voltage 30 VDC Max operating current 50 mA DC Speed coincidence detection ON whe...

Page 12: ...A R7M A75030 R7M AP75030 SGLFW 35A230 SGLFW 50A200 SGLGW 60A365A 1 5 kW XD 15 MN XD 15 MN00 E SGMPH 15A SGLFW 50A380 SGLFW 1ZA200 SGLGW 90A200A 3 Phase 400 VAC 0 5 kW XD 05 TN XD 05 TN00 E XD 05 TSD0...

Page 13: ...pose controllers 1 m R88A CPW001S or JZSP CKI01 1 2 m R88A CPW002S or JZSP CKI01 2 I Relay terminal block cable General purpose controller 1 m R88A CTW001N 2 m R88A CTW002N Relay terminal block XW2B 5...

Page 14: ...of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces m...

Reviews: