background image

1

iMarc

 SLV

Models 9820-2M and 9820-8M

Installation Instructions

Document Number 9820-A2-GN10-70

May 2003 

Contents

Product Documentation Online

.....................................................................

2

iMarc SLV 9820 In-Line Models

....................................................................

2

Package Checklist

........................................................................................

3

Preparation

...................................................................................................

3

Cables You Can Order

..................................................................................

4

iMarc SLV 9820 Front Panel

.........................................................................

5

iMarc SLV 9820 Rear Panel

..........................................................................

5

Installing the Power Supply and Cord

...........................................................

6

Connecting the COM Port to an Async Terminal or PC

................................

7

Menu Hierarchy

............................................................................................

8

A Quick Guide to Configuration

.................................................................... 11

Installing and Setting Up the iMarc SLV 9820 Unit

....................................... 12

Verifying that Self-Test Passed

..................................................................... 13

Setting the System Clock

.............................................................................. 13

Assigning the Node IP Address

.................................................................... 13

Configuring Physical Interfaces

.................................................................... 14

Automatic Configuration

............................................................................... 15

Connecting to the Network

........................................................................... 16

Setting Up Service Provider Connectivity at the Central Site

....................... 17

Configuring SNMP Trap Managers and Traps

.............................................. 17

Verifying the End-to-End Path

...................................................................... 18

Connecting to the DTE (Router or FRAD)

.................................................... 19

Important Safety Instructions

........................................................................ 21

Warranty, Sales, Service, and Training Information

...................................... 24

Trademarks

................................................................................................... 24

Patent Notification

......................................................................................... 24

 

NOTE: The FrameSaver

®

 

product line has been 
renamed to iMarc.

Summary of Contents for iMarc SLV 9820-2M

Page 1: ...Configuration 11 Installing and Setting Up the iMarc SLV 9820 Unit 12 Verifying that Self Test Passed 13 Setting the System Clock 13 Assigning the Node IP Address 13 Configuring Physical Interfaces 14...

Page 2: ...rc Operations Guide 9000 A2 GB33 To order a paper copy of a Paradyne document or to speak with a sales representative please call 1 727 530 2000 iMarc SLV 9820 In Line Models iMarc SLV 9820 models inc...

Page 3: ...within 6 feet of the iMarc unit A clean well lit and ventilated site that is free from environmental extremes One to two feet of clearance for cable connections A physical connection to the frame rel...

Page 4: ...cable 10 feet 3 meters X 21 DTE adapter cable EIA 530 A to X 21 1 foot 3 meters 9008 F1 521 035 0384 1031 035 0302 0131 Equipment with V 35 interfaces MS34 connectors V 35 cable kit which includes a...

Page 5: ...ct your sales representative to order cables iMarc SLV 9820 Front Panel 2 Mbps Model Shown iMarc SLV 9820 Rear Panel Safety Instructions Please refer to the Important Safety Instructions on page 21 98...

Page 6: ...OWER jack Make sure the locking tab snaps securely into the jack 2 Insert the socket end of the power cord into the power supply s receptacle 3 Plug the power cord into the grounded power outlet Verif...

Page 7: ...rt the other end of the cable into the PC or VT100 compatible terminal 4 Tighten the screws on each side of the connector to secure them 5 Install the ferrite choke as close to the COM port connector...

Page 8: ...IP Path ConnectionStatus Device Name IP Address Status Discovery Source PVC Connection Status Source Link DLCI EDLCI Status Primary Destination Status Alternate Destination Status IPRoutingTable Desti...

Page 9: ...on General Network Physical Frame Relay DLCI Records Data Ports Physical Frame Relay DLCI Records PVC Connections Source Link DLCI EDLCI Primary Destination Link DLCI EDLCI Alternate Destination Link...

Page 10: ...n Contact Date Time Administer Logins Login ID Password Access Level Change Operating Mode Back to Back Mode Standard Mode Select Software Release Current Release Alternate Release Switch Reset LMI Pa...

Page 11: ...ange 1 Press Ctrl a to switch to the function keys area at the bottom of the screen 2 Type s or S Save and press Enter The Save Configuration To menu appears 3 Press Enter again to save your changes t...

Page 12: ...ectivity between the central site and the remote sites From a network management perspective the central site iMarc unit should be configured for management from a Network Management System NMS throug...

Page 13: ...er cord The unit will perform the self test again If the failure reappears call your service representative for assistance Setting the System Clock Procedure To set up the system clock 1 Select System...

Page 14: ...priate Port Type 3 Press Ctrl a and Save your change s 4 Return to the Configuration Edit Display menu 5 Repeat Steps 2 through 4 for the data port Main Menu Configuration Data Ports Physical 6 Return...

Page 15: ...in the network DLCI NOTE When auto configuration creates a multiplexed DLCI but a standard DLCI is needed change the DLCI to standard from the network DLCI Records screen Configuration Network DLCI Re...

Page 16: ...If yes the network interface is set up correctly and it is operational If not make sure both ends of the network cable are properly seated and secured 4 Verify that the network physical options are c...

Page 17: ...elect it 4 Change the DLCI Type from Multiplexed to Standard The DLCI in connections Update DLCI usage as follows prompt appears 5 Select the Delete EDLCI Connections and Make a Mgmt Only PVC option P...

Page 18: ...rs must have been configured for the remote unit One of those trap managers must be the central site NMS Procedure 1 Select the IP Ping test Main Menu Test IP Ping 2 Enter the IP Address of the device...

Page 19: ...ification Check Is the Port OK LED on If yes the port is set up correctly and is operational If no check that both ends of the cable are properly seated and secured Check Health and Status messages in...

Page 20: ...act your service provider Next check the DLCI s status Checking PVC Connections Check PVC connections to verify that all PVCs including management PVCs are configured and to see whether the PVC is act...

Page 21: ...lable certified for use in the country of installation Paradyne power supply part number 327 0107 0031 is recommended This power supply includes a special mating connector for connection to this equip...

Page 22: ...pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment g...

Page 23: ...by Directive 93 68 EEC Directive 91 263 EEC Council Directive of 29 April 1991 on the approximation of the laws of the member states concerning telecommunication terminal equipment including mutual r...

Page 24: ...A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or...

Reviews: