![background image](http://html1.mh-extra.com/html/omron/v680-d1kp52mt/v680-d1kp52mt_user-manual_741386086.webp)
84
Sec
Ins
ta
lling RF Tags
RFID System
User's Manual
Section 4
Installation
V680-D1KP66T
RF Tag Installation Direction
Secure the RF Tag with M3 screws. Tighten the screws to a
torque of 0.6 N·m or less..
Effect of Metal behind RF Tags (Reference)
The V680-D1KP66T communications distance is reduced if there is any metal material behind the RF
Tag.
If the RF Tag is to be mounted to metal, then either use a V600-A86 Attachment (sold separately) or
insert a non-metal spacer (such as plastic or resin). The relationship between the distance from the RF
Tag to the metal surface and the communications distance is shown below.
The Attachment is 10 mm thick, and more than one Attachment can be stacked.
25
±
0.2
25
±
0.2
Two, M3
X
Y
M3 countersunk screw
V600-A86 Attachment Installation
0
10
20
30
40
50
60
70
80
90
100
10
20
30
40
50
(mm)
(%)
0
10
20
30
40
50
60
70
80
90
100
10
20
30
40
50
(mm)
(%)
V680-HS52 and V680-D1KP66T
V680-HS63 and V680-D1KP66T
X
Y
V680-D1KP66T
Communica-
tions
distance
V680-HS52
The comm
u
nications distance
w
itho
u
t
metal is 100
%
.
V680-HS63
V680-D1KP66T
Distance to metal (x)
Distance to metal (x)
Communica-
tions
distance
Metal on back
Metal on back
Metal
The comm
u
nications distance
w
itho
u
t
metal is 100
%
.
Metal
Install so that the mounting holes are aligned.