![background image](http://html1.mh-extra.com/html/omron/v680-d1kp52mt/v680-d1kp52mt_user-manual_741386079.webp)
77
RFID System
User's Manual
Sec
Ins
ta
lling RF Tags
Installation
V680-D1KP52M-BT01/-D1KP52M-BT11
RF Tag Installation Direction
1.
Turn the RF Tag clockwise, attach to the Mounting holes
.
V680-D1KP52M-BT01 is attached to the mounting holes in the M10,
V680-D1KP52M-BT11 to the mounting holes in the M8.
2.
Secure by tightening the bolts of the RF Tag.
When mounting the RF Tag, tighten the bolts to the following torques.
V680-D1KP52M-BT01: 24.5 N
⋅
m
V680-D1KP52M-BT11: 11 N
⋅
m
Mutual Interference with RF Tags (Reference)
Provide the mounting distances indicated below to prevent malfunctions due to mutual interference
when using more than one RF Tag.
Mounting Hole
RF Tag
RF Tag
25mm min.
25mm min.