![background image](http://html1.mh-extra.com/html/omron/v680-d1kp52mt/v680-d1kp52mt_user-manual_741386075.webp)
73
RFID System
User's Manual
Sec
Mount
ing Amp
lif
ie
rs
Installation
Mounting Amplifiers
V680-HA63A
Mounting to DIN Track
Note
1. Consider the height of the DIN Track.
2. Provide a space of at least 10 mm (i.e., at least two spacers) and attach them securely.
40
End Plate
10 mm min.
(See note 2.)
Mounting hook
(See note 1.)
DIN Track
Spacers
A
B
PFP-100N2
PFP-M
PFP-S
Mounting hook
End Plate
Spacer
DIN Track
1. When mounting the Amplifier to a DIN Track, first hook
section A to the Track and then press in direction B.
2. To remove the Amplifier from the DIN Track, first pull
out the mounting hook.