9-2
Section
Error Codes and Countermeasures
205
Error Code
Countermeasures
Description
E121
Decode error (Timing
pattern detection error in
X direction)
Check the printing of the reading code.
•
The timing pattern in the X direction may be
stained or damaged.
•
Codes may be bent.
E122
Decode error (Timing
pattern detection error in
Y direction)
Check the printing of the reading code.
•
The timing pattern in the Y direction may be
stained or damaged.
•
Codes may be bent.
E123
Decode error
(Cell recognition error)
Codes were restored to correct errors, but
not decoded correctly. Part of the codes may
be stained or damaged.
E150
Decode error
(No definition error)
The printing is in a special format and not
defined for the V530-R150.
•
Change the printing format.
•
The codes may be bent, stained, or dam-
aged.
Common Check Items for Error Codes E120 to E122
Check the gray edge value in
Reading Settings.
Refer to
Image Analysis/Line Bright for whether the value is
correct.
Confirming Pixels Per Cell
When
Display Settings/Detail Data is turned ON, the number
of pixels per cell is displayed together with detail information in
MON (monitor) or RUN mode. When reading is NG, confirm the
number of pixels per cell under
2. Image Analysis/Measure
Length.