Section
Trigger Inputs and Output Format
48
Send
<Footer>
Receive
Correct reading:
<Header >
<Number of Digits>
<Reading Data>
<FCS>
<Footer>
Incorrect reading:
Reading continues to be performed for the number of retries
specified in the setting conditions. An error code is output
when an error occurs.
<Header >
<Error Code>
<FCS>
<Footer>
When Reading Accuracy is ON:
<Header > <Reading Accuracy>
<Reading Data>
<FCS>
<Footer>
The judgment (reading accuracy) of 10 readings is dis-
played. When the reading accuracy is 0%, “?” is displayed
for reading data.
When Coincidence Judgment is ON:
<Header >
<Number>
<Reading Data>
<FCS>
<Footer>
Coincident with registered data 0 : 00
Coincident with registered data 1 : 01
Coincident with registered data 2 : 02
Coincident with registered data 3 : 03
Not coincident with registered data 0 to 3: NG
Continuous Reading (@GC, @SC)
1:1 Connection
Performs continuous reading until the stop command (@SC ) is
sent.