6-2
Section
MON (Monitor) Mode
152
Reading Time
Reading Judgment
NG will be displayed when reading is
not performed correctly or reading
data is not coincident with registered
data for coincidence judgments 0 to 3.
Displayed Images. Press the SHIFT + Up/Down Keys to switch images.
ABCDE12345
Data obtained
205ms
Types of Displayed Image
Freeze (
)
A still image immediately after measurement. The memory number
(0 to 23) under which the image is stored is displayed in
. When
reading moving objects, display freeze images.
Through
A live image from the Camera. When reading is performed on
through images, a delay of 33.3 to 66.6 ms max. (depending on
timing of command inputs) will occur before starting to load images.
Measurement
command
Image input
Camera
run-cycle
33.3 ms
(Image transferred
to V530)
66.6 ms
Memory
A reading image stored in the past.
The reading images which are coincident with image storage
conditions are stored in memory 0 to 23.
How to set storage conditions of images.
→
Image 0
An image after filtering according to the settings in
SET/Image
Adjust.
Reading is performed on the image after filtering.
Image 1
An edge detection image for Data Matrix processing. (For a scene
in which conditions are set for QR Codes, this will be same as the
Image 0.)