3-2
Section
Trigger Input and Output Format
26
specifications settings.
The default setting is NG: ON.
→
DO0 to DO3 Terminals
While the coincidence judgment function is ON, the signals are
as follows:
How to set coincidence judgment function
→
Coincident with registered data 0: DO0 terminal turns ON.
Coincident with registered data 1: DO1 terminal turns ON.
Coincident with registered data 2: DO2 terminal turns ON.
Coincident with registered data 3: DO3 terminal turns ON.
Note The initial status of the output terminals is OFF. The terminals,
however, may turn ON for approximately 0.5 s when the power is
turned ON. Be sure to allow for this when connecting to an exter-
nal device.