60
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
V500-R521B2/C2
User’s Manual
Section 4
Setting Method
Hatching parts are the changed point from the factory default setting.
Collective setting
Menu sheet
Command
Setting for connecting link unit (V700-L12)
UC
Item
Setting content
Corresponding
command
Types of code, which is possible to read EAN/UPC, CODE39, NW-7, STF, ITF
J1+R4+B2+B3
+R7+R8
Number of reading digits
No designated number of digits
H0
Detail condition CODE39 detail setting Invalid C/Dof CODE39
C0
Transfer C/D of CODE39
C2
Transfer ST/SP of CODE39
D1
NW-7 detail setting
Invalid C/D of NW-7
F7
Transfer C/D of NW-7
F5
Transfer ST/SP of NW-7 (abcd/abcd)
F4
ITF/STF detail setting
Invalid C/D of ITF/STF
G0
Transfer C/D of ITF/STF
G2
Reading
condition
Reading system
Trigger reading
S8
Reading operation
Single reading
S0
Reading valid time
T 2 sec.
Y2
Number of reading
coincidence
Twice (Verification: once)
X1
Communication
condition
Communication speed 9600 bps
K6
Data length
8-bit
L1
Parity
Even number
L3
Stop bit length
1-bit
L5
Header
None
1Y
Footer
CR
1Z+1C
Transfer number of
digits
Not transferred
2Z
RS/CS control
None
P0
CS waiting time
Infinity
I0
Communication
protocol
No protocol system
P5
Process when reading
is NG
Transfer ? (CR), > (CR)
5H
LED illumination
LED illumination time after decoding is 200 ms.
T5
Buzzer sound
Buzzer sound duration after decoding is 200 ms. W5
Buzzer sound volume
Max.
T0
Buzzer frequency
3 kHz, 2 kHz
W2
External trigger signal
Negative logic (L active)
8B
READ OK/NG signal output
Output
8Q
READ OK/NG signal output system
Trigger synchronous system, positive logic
(H active)
8C
V500-R521.book 60 ページ 2008年7月18日 金曜日 午後1時1分