Section 4
Setting Method
Collective setting
Collective setting of conditions appropriate for connection of programmable controller
(UB) and for connection of multi-drop using link unit (UC) is allowed.
Hatching parts are the changed point from the factory default setting.
Collective setting
Menu sheet
Command
Setting of programmable controller connection
UB
Item
Setting content
Corresponding
command
Types of code, which is possible to read EAN/UPC, CODE39, NW-7, STF, ITF
J1+R4+B2+B3
+R7+R8
Number of reading digits
No designated number of digits
H0
Detail condition CODE39 detail setting Invalid C/D of CODE39
C0
Transfer C/D of CODE39
C2
Transfer ST/SP of CODE39
D1
NW-7 detail setting
Invalid C/D of NW-7
F7
Transfer C/D of NW-7
F5
Transfer ST/SP of NW-7 (abcd/abcd)
F4
ITF/STF detail setting
Invalid C/D of ITF/STF
G0
Transfer C/D of ITF/STF
G2
Reading
condition
Reading system
Trigger reading
S8
Reading operation
Single reading
S0
Reading valid time
T 2 sec.
Y2
Number of reading
coincidence
Twice (Verification: once)
X1
Communication
condition
Communication speed 9600 bps
K6
Data length
7-bit
L0
Parity
Even number
L6
Stop bit length
2-bit
L6
Header
None
1Y
Footer
CR
1Z+1C
Transfer number of digits Not transferred
2Z
RS/CS control
None
P0
CS waiting time
Infinity
I0
Communication
protocol
No protocol system
P5
Process when reading is NG Transfer ? (CR), > (CR)
5H
LED illumination
LED illumination time after decoding is 200 ms.
T5
Buzzer sound
Buzzer sound duration after decoding is 200 ms. W5
Buzzer sound volume
Max.
T0
Buzzer frequency
3 kHz, 2 kHz
W2
External trigger signal
Negative logic (L active)
8B
READ OK/NG signal output
Output
8Q
READ OK/NG signal output system
Trigger synchronous system, positive logic
(H active)
8C