58
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
V500-R521B2/C2
User’s Manual
Section 4
Setting Method
Return to factory default setting
Initial setting
Menu sheet
Command
Factory default setting
UA
Item
Setting content
Corresponding
command
Types of code, which is possible to read EAN/UPC, CODE39, NW-7, STF, ITF
J1+R4+B2+B3
+R7+R8
Number of reading digits
No designated number of digits
H0
Detail condition CODE39 detail setting Invalid C/D of CODE39
C0
Transfer C/D of CODE39
C2
Transfer ST/SP of CODE39
D1
NW-7 detail setting
Invalid C/D of NW-7
F7
Transfer C/D of NW-7
F5
Transfer ST/SP of NW-7 (abcd/abcd)
F4
ITF/STF detail setting
Invalid C/D of ITF/STF
G0
Transfer C/D of ITF/STF
G2
Reading
condition
Reading system
Trigger reading
S8
Reading operation
Single reading
S0
Reading valid time
T 2 sec.
Y2
Number of reading
coincidence
Twice (Verification: once)
X1
Communication
condition
Communication speed 9600 bps
K6
Data length
8-bit
L1
Parity
None
L2
Stop bit length
1-bit
L5
Header
None
1Y
Footer
CR
1Z+1C
Transfer number of
digits
Not transferred
2Z
RS/CS control
None
P0
CS waiting time
Infinity
I0
Communication
protocol
No protocol system
P5
Process when reading
is NG
No process (Nothing is transferred)
5E
LED illumination
LED illumination time after decoding is 200 ms.
T5
Buzzer sound
Buzzer sound duration after decoding is 200 ms. W5
Buzzer sound volume
Max.
T0
Buzzer frequency
3 kHz, 2 kHz
W2
External trigger signal
Negative logic (L active)
8B
READ OK/NG signal output
Output
8Q
READ OK/NG signal output system
Trigger synchronous system, positive logic
(H active)
8C