69
V500-R521B2/C2
User’s Manual
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
Section 4
Setting Method
Setting for number of reading digit
When the number of digit is fixed, designate the number of digit to improve reliability.
For number of digit, two types (A and B) can be set.
In case of the bar code including C/D, count the C/D as one digit.
*1
After reading this menu sheet, read the bar code of the number of digit you want to register twice,
continuously. When the number of digit is one type, set A and B to the same setting.
*2
After transmitting this command, transmit the character string of the bar code you want to register,
continuously.
p.54
Menu sheet
Command
Menu sheet
Command
Number of digit is not designated.
(Factory default setting)
None
Designation of number of digit A *2
(No menu sheet)
7V
Designation of number of digit A (Bar
code reading system) *1
None
Designation of number of digit B *2
(No menu sheet)
7W
Designation of number of digit B (Bar
code reading system) *1
None
V500-R521.book 69 ページ 2008年7月18日 金曜日 午後1時1分