83
V500-R521B2/C2
User’s Manual
Se
ct
io
n
4
Me
nu Shee
t/Co
mmand List
Section 4
Setting Method
Setting related to sorting read
Bar code data to read are registered in this bar code reader beforehand and only the
registered bar codes are read using this function. When the read bar code does not
coincide with the registered data, buzzer sounds.
Up to 5 types of bar codes can be registered.
*1
Execute the command "UE" to start sorting read operation.
Menu sheet
Command
Register one character each using
command. (*1)
Register with regular expression. (*1)
7Y
Sorting read operation starts.
UE
When you enter the command "UE", reading system and communication specification are set as
follows. When sorting read function is used, do not change the setting basically.
To change a part of communication condition, etc, change it after you input command "UE" and
sorting read operation starts.
Item
Setting content
Types of code, which is possible to read
Reading permission for all types
Number of reading digits
No designated number of digits
Reading system Reading trigger
Valid (Not full-time reading but trigger is used)
Reading operation
Single reading
Reading valid time
T 2 sec.
Number of reading
coincidence
Twice (Verification: once)
Communication speed
9600 bps
Data length
8-bit
Parity
None
Communication
condition
Stop bit length
1-bit
Header
None
Footer
CR
Transfer number of digits
Not transferred
RS/CS control
None
CS waiting time
Infinity
Communication protocol
No protocol system
Process when reading is NG
No process (Nothing is transferred)
V500-R521.book 83 ページ 2008年7月18日 金曜日 午後1時1分