Basic Knowledge of Operation
Process for failed reading
The error message transmitted when reading fails depends on the setting.
Setting method p.72
Data transfer contents of each reading code type
Setting method p.63
Output item
Description
Factory default
setting
Error message - No label
This message is returned when no code exists
in the field of view.
Not transmitted
Error message - Decoding failure
This message is returned when the code
cannot be read.
Not transmitted
Reading code
Description
UPC-A
You can select whether or not to transfer the head character “0” for
transfer digit number adjustment and check digit C/D. (“0” is an
additional character to be combined with C/D to adjust the number of
digits to be identical to JAN/EAN-13.)
0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C/D
S: Number system character (Automatically decided according to the
combination of each character of X1 to X10.)
UPC-E
You can select whether or not to transfer the head character “0” for
transfer digit number adjustment and check digit C/D. (“0” is an
additional character to be combined with C/D to adjust the number of
digits to be identical to JAN/EAN-13.)
0 S X1 X2 X3 X4 X5 X6 C/D
S: Number system character (Automatically decided according to the
combination of each character of X1 to X10.)
JAN/EAN
Reading data (8-digit or 13-digit) is transferred as it is.
ITF, STF (2 of 5 bars)
Transfers in the order from the next character of the start code to the
character before the stop code. (The start code and stop code are not
transferred.)
NW-7, CODE39
You can select whether or not to transfer the start code and stop code.
When the transfer of the start code and stop code is permitted, you can
select whether the transferred start/stop code of NW-7 is in lower-case
“a/b/c/d” or in upper-case “A/B/C/D”.
The transfer start/stop code of CODE39 is “*”.
EAN128
When the EAN128 conversion is enabled, the control character “]C1”
(ASCII code: 5D, 43, 31) which indicates EAN128 is added to the head
of the transfer data. Also, the FNC1 character, which is used as a
separating character, is replaced with the GS (ASCII code: 1DH)
character before it is transferred.
2D code
Only the reading data is transferred.
Communication with upper equipment
Check that the product has started up, and then start communication with upper equipment.
Indefinite signals may be generated from the upper interface while the product starts up. Clear the
receive buffer of the devices before starting initial operation.