27
V400-R1CF/R1CS
User’s Manual
Section
2
Prel
iminary Examination
Section 2
Introduction Procedure
Reading angle performance
Pitch angle (
α
)
In the following conditions, readable up to
α
= 50° on either side.
• Code:
Resolution = 0.254 mm, CODE39 (2 digits),
MRD 63% (PCS = 0.9)
• Reading distance:
57 mm from the case end
• Installation condition: Skew angle
β
= 15°, tilt angle
γ
= 36°, curvature R =
∞
Skew angle (
β
)
In the following conditions, readable up to
β
= +/-50°.
• Code:
Resolution = 0.254 mm, CODE39 (2 digits),
MRD 63% (PCS = 0.9)
• Reading distance:
57 mm from the case end
• Installation condition: Pitch angle
α
= 0°, tilt angle
γ
= 360°, curvature R =
∞
Reading performance for bar codes on a highly gloss surface such as glossy paper or a card case
may be impaired because reflected illumination LED light or room illumination light enters the
reading window.
If reflected illumination LED light is the culprit, reading performance can be improved by providing
an angle of about 15° in the skew direction or turning off the illumination LED light.