35
V400-R1CF/R1CS
User’s Manual
Section
2
Prepa
ration
Section 2
Introduction Procedure
Preparation
This section describes the setting method based on preliminary examination. Perform a test to
check whether the intended code is read and set the reading conditions for the purpose.
Testing
You can check how stably the intended code can be read.
Read the code at rest ten times and calculate the reading rate.
Entering the reading rate measurement mode
1.
Place the code in the reading position.
2.
Input the command “[XU8”.
The reader enters the reading rate measurement mode.
The reading rate in every 10 reading operations is measured.
3.
To exit the reading rate measurement mode, restart the reader.
The reader returns to the normal measurement mode.
Output format
In reading rate measurement mode, the reading rate in every 10 reading operations is
output continuously to the upper equipment.
Communication data format
Do not execute write command “Z2” to nonvolatile memory.
A sample setting condition is overwritten and stored, which erases the already set reading condition.
10/10
ABCDEFG
The number of times of successful decoding (no verification)
10 reading tries
Correct reading data
Header
Footer
Header
Footer
Correct
reading data
Footer