37
V400-R1CF/R1CS
User’s Manual
Section
2
Prepa
ration
Section 2
Introduction Procedure
Setting the reading conditions
There are the following two setting methods for the reader. Select either method
according to the condition.
Read the menu sheet.
The menu sheet is a special code used to set the reader function.
Setting can be changed by reading this menu sheet.
1.
Read the menu sheet “ZZ” that starts/ends the setting procedure.
The buzzer sounds continuously, indicating that the reader has entered the setting mode.
2.
Read the menu sheet “U2” that restores the factory default settings.
3.
Read the menu sheet for the setting item you want to change.
Menu Sheet/Command List p.56
4.
To finish, read the menu sheet “ZZ” that starts/ends the setting procedure.
The buzzer stops and the reader returns to the normal mode.
Setting method
Description
Read the menu sheet.
This method reads the menu sheet of the function you want to set.
This is convenient for the initial setting and when testing.
Input a command from the upper
equipment.
This method inputs a command from the upper equipment.
This is convenient when changing setup according to the type of
code.
_ZZ_
_U2_
_ZZ_