402
11-1 Communications Procedure
Command Chart
The commands listed in the chart below can be used for host link communica-
tions with the C200HS. These commands are all sent from the host computer to
the PC.
Header code
PC mode
Name
Page
RUN
MON
PRG
g
RR
Valid
Valid
Valid
IR/SR AREA READ
407
RL
Valid
Valid
Valid
LR AREA READ
407
RH
Valid
Valid
Valid
HR AREA READ
408
RC
Valid
Valid
Valid
PV READ
408
RG
Valid
Valid
Valid
TC STATUS READ
409
RD
Valid
Valid
Valid
DM AREA READ
409
RJ
Valid
Valid
Valid
AR AREA READ
410
WR
Not valid
Valid
Valid
IR/SR AREA WRITE
410
WL
Not valid
Valid
Valid
LR AREA WRITE
411
WH
Not valid
Valid
Valid
HR AREA WRITE
411
WC
Not valid
Valid
Valid
PV WRITE
412
WG
Not valid
Valid
Valid
TC STATUS WRITE
412
WD
Not valid
Valid
Valid
DM AREA WRITE
413
WJ
Not valid
Valid
Valid
AR AREA WRITE
413
R#
Valid
Valid
Valid
SV READ 1
414
R$
Valid
Valid
Valid
SV READ 2
415
R%
Valid
Valid
Valid
SV READ 3
416
W#
Not valid
Valid
Valid
SV CHANGE 1
417
W$
Not valid
Valid
Valid
SV CHANGE 2
417
W%
Not valid
Valid
Valid
SV CHANGE 3
418
MS
Valid
Valid
Valid
STATUS READ
419
SC
Valid
Valid
Valid
STATUS WRITE
420
MF
Valid
Valid
Valid
ERROR READ
421
KS
Not valid
Valid
Valid
FORCED SET
422
KR
Not valid
Valid
Valid
FORCED RESET
423
FK
Not valid
Valid
Valid
MULTIPLE FORCED SET/RESET
424
KC
Not valid
Valid
Valid
FORCED SET/RESET CANCEL
425
MM
Valid
Valid
Valid
PC MODEL READ
425
TS
Valid
Valid
Valid
TEST
426
RP
Valid
Valid
Valid
PROGRAM READ
426
WP
Not valid
Not valid
Valid
PROGRAM WRITE
427
MI
Not valid
Not valid
Valid
I/O TABLE GENERATE
427
Valid
Valid
Valid
COMPOUND COMMAND
427
XZ
Valid
Valid
Valid
ABORT (command only)
429
::
Valid
Valid
Valid
INITIALIZE (command only)
430
IC
---
---
---
Undefined command (response only)
430
Communications Procedure
Section 11-1