![background image](http://html1.mh-extra.com/html/omron/sysmac-c200hs/sysmac-c200hs_operation-manual_742436022.webp)
9
TRSM(45) TRACE MEMORY SAMPLE
MCRO(99) MACRO
MAX(--)
FIND MAXIMUM
MIN(--)
FIND MINIMUM
SUM(--)
SUM
SRCH(--)
DATA SEARCH
FPD(--)
FAILURE POINT DETECTION
PID(--)
PID CONTROL
HEX(--)
ASCII TO HEX
XDMR(--)
EXPANSION DM READ
DSW(--)
DIGITAL SWITCH INPUT
TKY(--)
TEN-KEY INPUT
MTR(--)
MATRIX INPUT
HKY(--)
16-KEY INPUT
ADBL(--)
DOUBLE BINARY ADD
SBBL(--)
DOUBLE BINARY SUBTRACT
MBSL(--)
DOUBLE SIGNED BINARY MULTIPLY
DBSL(--)
DOUBLE SIGNED BINARY DIVIDE
MBS(--)
SIGNED BINARY MULTIPLY
DBS(--)
SIGNED BINARY DIVIDE
FCS(--)
FRAME CHECKSUM
7SEG(--)
7-SEGMENT DISPLAY OUTPUT
RXD(--)
RECEIVE
TXD(--)
TRANSMIT
CPS(--)
SIGNED BINARY COMPARE
CPSL(--)
SIGNED DOUBLE BINARY COMPARE
NEG(--)
2’S COMPLEMENT
NEGL(--)
DOUBLE 2’S COMPLEMENT
ZCPL(--)
DOUBLE AREA RANGE COMPARE
AVG(--)
AVERAGE VALUE
SCL(--)
SCALE
SET
SET
RSET
RESET
TTIM(87)
TOTALIZING TIMER
XFRB(62)
TRANSFER BITS
ZCP(88)
AREA RANGE COMPARE
1-8-4 Wide Selection of Special I/O Units
C200HS Systems can be configured in a variety of ways, using High-density I/O
Units, High-speed Counters, Position Control Units, Analog I/O Units, Tempera-
ture Sensor Units, ASCII Units, Voice Units, ID Sensor Units, Fuzzy Logic Units,
Cam Positioner Units, and so on.
1-8-5 Improved Interrupt Functions
Scheduled Interrupts
The C200HS’s scheduled interrupt function has been improved so that the inter-
rupt interval can be set in 1 ms units rather than the 10 ms units in the C200H.
When the interrupt mode is set to C200HS mode, the interrupt response time is
only 1 ms max. (excluding the input ON/OFF delays). When a Communications
Unit is used with the C200HS-CPU31-E/CPU33-E CPU, the interrupt response
time is 10 ms max.
Input Interrupts
Up to 8 interrupt subroutines can be executed by inputs to a C200HS-INT01 In-
terrupt Input Unit mounted to the C200HS. When the interrupt mode is set to
C200HS mode, the interrupt response time is only 1 ms max. (excluding the in-
put ON/OFF delays). When a Communications Unit is used with the C200HS-
CPU31-E/CPU33-E CPU, the interrupt response time is 10 ms max.
1-8-6 SYSMAC NET Link and SYSMAC LINK Capabilities
The SYSMAC NET Link and SYSMAC LINK Systems are high-speed FA net-
works which can be used with the C200HS-CPU31-E and C200HS-CPU33-E
CPUs and the following Units:
SYSMAC NET Link Unit:
C200HS-SNT32
SYSMAC LINK Units:
C200HS-SLK12 (optical fiber cable)
C200HS-SLK22 (coaxial cable)
Data can be exchanged with the PCs in a SYSMAC NET Link or SYSMAC LINK
System using the SEND and RECV instructions.
New C200HS Features
Section 1-8