354
Example
The following examples shows programming MTR(––) in a scheduled subrou-
tine, where IORF(97) is programmed to ensure that the I/O words used by
MTR(––) are refreshed each time MTR(––) is executed.
INT(89)
001
004
# 0002
INT(89)
000
004
# 0002
SBN(92)
99
MTR(––)
S
D1
D2
IORF(97)
D1
D2
RET(93)
END(01)
Flags
ER:
Indirectly addressed DM word is non-existent. (Content of
DM word is
not BCD, or the DM area boundary has been exceeded.)
25403:
SR 25403 is ON while MTR(––) is being executed.
5-29 Special I/O Unit Instructions
The Special I/O Unit instructions are used to transfer data to and from the
memory of the specified Special I/O Unit.
5-29-1
SPECIAL I/O UNIT READ – IORD(––)
C:
Control code
IR, SR, AR, DM, HR, TC, LR, #
S:
Source information
IR, SR, AR, DM, HR, TC, LR, #
Operand Data Areas
D:
First destination word
IR, SR, AR, DM, HR, TC, LR
Ladder Symbols
IORD(––)
C
S
D
@IORD(––)
C
S
D
Limitations
Only Special I/O Units mounted to the PC’s CPU Rack or Expansion I/O Racks
can be specified.
The last three digits of S must be BCD (from 001 to 128).
Special I/O Unit Instructions
Section 5-29
Summary of Contents for SYSMAC C200HE
Page 1: ...Cat No W303 E1 09 OPERATION MANUAL Programmable Controllers C200HX C200HG C200HE ...
Page 2: ......
Page 3: ...C200HX C200HG C200HE Programmable Controllers Operation Manual Revised August 2004 ...
Page 6: ...vi ...
Page 10: ......
Page 12: ......
Page 380: ......
Page 410: ......
Page 438: ......
Page 464: ......
Page 474: ......
Page 522: ......
Page 538: ......
Page 552: ...534 Programmer Program Date Page Word Contents Notes Word Contents Notes Data Storage ...
Page 554: ......
Page 560: ......
Page 584: ......
Page 585: ......
Page 586: ...W303 E1 09 ...