S
P E C I F I C A
T I O N S
Mechani
cal
15
Safety Edge Controllers Manual 99640-0010 Rev.P
Original Instructions
Switching Times Aux Outputs:
* These contact must never to be used in the safety circuit.
— Response time 0.5 s
— Release time 3 s
6.3. M
ECHANICAL
Enclosure:
Polyamide, Self extinguishing in accordance with UL 94-
V2
DIN Rail Mount Dimensions:
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99.0 mm (3.89in.)
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22.5 mm (0.885in.)
Depth: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114.0 mm (4.89in.)
Environmental Protection Rating:
Housing: IP40; Terminal: IP20.
Operating Temperature:
-20°C to +55°C
Approvals:
— Conforming to standards
ISO 13849-1:2008
— Category
3
— Other approvals: CE, TUV
— Reliability
Parameters:
PFHd [1/h]: 8.84e-8
PL d
MTTFd[a] = 329
DC[%] = 97