![background image](http://html.mh-extra.com/html/omron/scc-1224/scc-1224_installation-and-operating-manual_1633415014.webp)
S P E C I F I C A T I O N S
Maximum Response Time: <13 ms
14
Safety Edge Controllers Manual 99640-0010 Rev.P
Original Instructions
6
S
PECIFICATIONS
6.1. M
AXIMUM
R
ESPONSE
T
IME
: <13
MS
Indicators:
— Green LED = Power On
— Yellow LED = Sensor Activated
— Red LED #1 = Safety Circuit Interrupted
— Yellow LED = Auxiliary Output Activated
6.2. E
LECTRICAL
Supply Voltage:
115 VAC, 50Hz. 3.3 VA or
24 VDC, 1.5 W or
24 VAC, 2.1 VA
Input:
2-Wire, Safety Edge with 8.2 K ohm resistor
Safety Outputs:
2 Safety Outputs max. current and voltage
4A @ 250 VAC, 4 A @ 30VDC.
2 Safety Outputs current and voltage, electrical life at 2.5A @ 250 VAC,
2.5A @ 30VDC.
Auxiliary Output:
1 Aux. Output, max. current and voltage
4A @ 250 VAC, 4A @ 30VDC.
1 Aux. Output current and voltage, electrical life at 2.5A @ 250 VAC,
2.5A @ 30VDC.
*Auxiliary outputs must never to be used in the safety circuit.
Switching Times Safety Outputs
— Response time < 13 ms;
— Release time 1 s